{"product_id":"abb-tu810v1-3bse013230r1-s800-i-o-compact-termination-unit","title":"ABB TU810V1 3BSE013230R1 S800 I\/O Compact Termination Unit","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB TU810V1 (3BSE013230R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a compact Module Termination Unit (MTU) within the S800 I\/O system architecture. This unit provides the physical and electrical interface between field wiring and S800 I\/O modules. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, facilitating secure signal routing for various digital and analog process signals. It acts as the structural foundation for I\/O modules, enabling rapid hardware swaps without disturbing field-side terminal connections.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe TU810V1 utilizes a space-saving design to manage high-density I\/O signals:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTU810V1 \/ 3BSE013230R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS800 I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e58.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Depth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS Directive 2011\/65\/EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBattery Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (0 Batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Cabinet Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 58.5 mm width allows for high-density DIN-rail mounting. This design maximizes the number of I\/O points within limited control cabinet space, reducing the overall hardware footprint in large-scale DCS installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe MTU separates the I\/O electronics from the field wiring terminals. This architecture allows maintenance personnel to replace faulty I\/O modules instantly without disconnecting a single field wire, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Electrical Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrecision-engineered screw terminals ensure low-resistance connections for both shielded and unshielded cables. This mechanical stability prevents intermittent signal loss caused by industrial vibrations or thermal expansion in heavy-duty environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Backplane Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TU810V1 establishes a direct, high-integrity link to the ModuleBus. This ensures deterministic data exchange between the I\/O module and the AC 800M controller, maintaining high-speed process response for time-critical control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Battery Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit utilizes purely passive mechanical and electrical routing for its termination functions. This battery-free design eliminates periodic maintenance checks and prevents logic loss or hardware failure due to chemical leakage or power depletion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the TU810 and the TU810V1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TU810V1 represents the updated version of the standard TU810, offering improved mechanical tolerances and compliance with the latest environmental directives like RoHS. It functions as a direct, drop-in replacement for the original TU810.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the TU810V1 with high-voltage 230V AC signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The TU810V1 supports applications up to a maximum of 50V. For 230V AC digital signals, you must select an MTU specifically rated for higher voltage levels, such as the TU812 or similar models.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or surplus unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely not. We guarantee this TU810V1 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware. It arrives in the original ABB factory packaging with all security seals, 3BSE013230R1 part numbers, and technical documentation intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the TU810V1 include the I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The TU810V1 is the Module Termination Unit (base) only. You must purchase the compatible S800 I\/O module (such as the DI810 or DO810) separately to complete the assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53095998259384,"sku":"TU810V1 3BSE013230R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/TU810V13BSE013230R1.jpg?v=1774429926","url":"https:\/\/www.globalpetroparts.com\/products\/abb-tu810v1-3bse013230r1-s800-i-o-compact-termination-unit","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}