{"product_id":"ai825-3bse036456r1-analog-input-module-4-channel-abb-s800-i-o","title":"AI825 3BSE036456R1 Analog Input Module, 4-Channel | ABB S800 I\/O","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe ABB AI825 3BSE036456R1 is a 4-channel galvanic individually isolated analog input module designed for S800 I\/O systems to measure and process flexible bipolar current and voltage signals from field instruments to process controllers.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProduct Type: Analog Input Module\u003c\/li\u003e\n  \u003cli\u003ePart Number: 3BSE036456R1\u003c\/li\u003e\n  \u003cli\u003eModel: AI825\u003c\/li\u003e\n  \u003cli\u003eMechanics: S800\u003c\/li\u003e\n  \u003cli\u003eNumber of Channels: 4\u003c\/li\u003e\n  \u003cli\u003eIsolation: Individually isolated, channel-to-channel and to circuit common\u003c\/li\u003e\n  \u003cli\u003eSignal Specification (Current): -20 to +20 mA, 0 to 20 mA, 4 to 20 mA\u003c\/li\u003e\n  \u003cli\u003eSignal Specification (Voltage): -10 to +10 V, 0 to 10 V, 2 to 10 V\u003c\/li\u003e\n  \u003cli\u003eResolution: 14 bit plus sign\u003c\/li\u003e\n  \u003cli\u003eInput Impedance (Voltage Input): 10 MΩ\u003c\/li\u003e\n  \u003cli\u003eInput Impedance (Current Input): 50 Ω\u003c\/li\u003e\n  \u003cli\u003eUnder\/Over Range: ±15%\u003c\/li\u003e\n  \u003cli\u003eMaximum Error: 0.1%\u003c\/li\u003e\n  \u003cli\u003eTemperature Drift (Voltage, 0 to 10V): Max. 47 ppm\/°C\u003c\/li\u003e\n  \u003cli\u003eTemperature Drift (Voltage, ±10V): Max. 34 ppm\/°C\u003c\/li\u003e\n  \u003cli\u003eTemperature Drift (Current, 0 to 20mA): Max. 78 ppm\/°C\u003c\/li\u003e\n  \u003cli\u003eTemperature Drift (Current, ±20mA): Max. 57 ppm\/°C\u003c\/li\u003e\n  \u003cli\u003eInput Filter Rise Time (Voltage Input): 115 ms\u003c\/li\u003e\n  \u003cli\u003eInput Filter Rise Time (Current Input): 130 ms\u003c\/li\u003e\n  \u003cli\u003eUpdate Cycle Time: \u0026lt; 10 ms\u003c\/li\u003e\n  \u003cli\u003eMaximum Field Cable Length: 600 meters\u003c\/li\u003e\n  \u003cli\u003eCMRR (50Hz, 60Hz): 120 dB\u003c\/li\u003e\n  \u003cli\u003eNMRR (50Hz): \u0026gt; 40 dB\u003c\/li\u003e\n  \u003cli\u003eNMRR (60Hz): \u0026gt; 55 dB\u003c\/li\u003e\n  \u003cli\u003eRated Insulation Voltage: 250 V\u003c\/li\u003e\n  \u003cli\u003eDielectric Test Voltage (Channel-to-Channel): 1900 V d.c.\u003c\/li\u003e\n  \u003cli\u003eDielectric Test Voltage (Channel-to-Ground\/System): 3250 V d.c.\u003c\/li\u003e\n  \u003cli\u003ePower Dissipation: Typ. 2.5 W, Max. 3.2 W\u003c\/li\u003e\n  \u003cli\u003eCurrent Consumption +5 V Modulebus: Typ. 70 mA, Max. 100 mA\u003c\/li\u003e\n  \u003cli\u003eCurrent Consumption +24 V Modulebus): Typ. 90 mA, Max. 110 mA\u003c\/li\u003e\n  \u003cli\u003eCurrent Consumption +24 V External: 0 mA\u003c\/li\u003e\n  \u003cli\u003eHART Communication Compatibility: Yes (Withstand)\u003c\/li\u003e\n  \u003cli\u003eSOE: No\u003c\/li\u003e\n  \u003cli\u003eRedundancy: No\u003c\/li\u003e\n  \u003cli\u003eHigh Integrity: No\u003c\/li\u003e\n  \u003cli\u003eIntrinsic Safety: No\u003c\/li\u003e\n  \u003cli\u003eCompatible Module Termination Units (MTUs): TU811, TU813, TU831\u003c\/li\u003e\n  \u003cli\u003eMTU Keying Code: DA\u003c\/li\u003e\n  \u003cli\u003eWidth: 45 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 102 mm (111 mm including connector)\u003c\/li\u003e\n  \u003cli\u003eHeight: 119 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides 4 channels featuring strict channel-to-channel individual galvanic isolation for premium signal integrity.\u003c\/li\u003e\n  \u003cli\u003eSupports a versatile array of bipolar and unipolar current and voltage process ranges per channel.\u003c\/li\u003e\n  \u003cli\u003eUtilizes high-resolution 14-bit plus sign conversion hardware for ultra-precise instrument tracking.\u003c\/li\u003e\n  \u003cli\u003eIncludes integral input shunt resistors designed to withstand up to 30 V d.c. overvoltage faults.\u003c\/li\u003e\n  \u003cli\u003eMaintains uninterrupted technical performance while withstanding standard superimposed HART communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module onto a compatible S800 Module Termination Unit (MTU) including TU811, TU813, or TU831.\u003c\/li\u003e\n  \u003cli\u003eConnect field measurement cabling to the designated MTU poles adhering to clear voltage or current channel layouts.\u003c\/li\u003e\n  \u003cli\u003eEnsure grounding infrastructure complies fully with the 3250 V d.c. channel-to-ground dielectric isolation framework.\u003c\/li\u003e\n  \u003cli\u003eVerify the MTU mechanical keying position is fixed precisely to code DA before inserting the module into place.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53617370890424,"sku":"AI825","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/AI820.png?v=1782197533","url":"https:\/\/www.globalpetroparts.com\/products\/ai825-3bse036456r1-analog-input-module-4-channel-abb-s800-i-o","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}