{"product_id":"allen-bradley-1492-acable025ud-1492-pre-wired-analog-cable-assembly","title":"Allen-Bradley 1492-ACABLE025UD 1492 Pre-Wired Analog Cable Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1492-ACABLE025UD establishes a secure, shielded interface path between Bulletin 1756 ControlLogix analog, RTD, or thermocouple input modules and external 1492 interface blocks. This premium pre-wired analog cable preserves micro-volt signals, eliminates manual wire stripping, and prevents the installation errors that cause measurement drift in complex process control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1492-ACABLE025UD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePre-Wired Shielded Analog I\/O Cable Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 Meters (8.2 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBulletin 1756 Analog I\/O, RTD, and Thermocouple Input Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-Voltage Analog and Temperature Sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCable and Wire \/ Industrial Automation Connectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.40 lbs (0.64 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuppresses Electromagnetic Interference (EMI):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable features dedicated shielding layer architecture that repels high-frequency noise from nearby variable frequency drives (VFDs) and high-voltage power lines. This engineering configuration protects delicate thermocouple and RTD millivolt inputs from signal corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Temperature Loop Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe factory-terminated connectors plug directly into 1756 I\/O chassis modules. This design bypasses traditional, tedious point-to-point manual screwdriver wiring, saving critical field-commissioning hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Measurement Cross-Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandardized pin assignments guarantee precise tracking between field transmitter terminals and corresponding PLC input addresses, ensuring absolute measurement fidelity from day one.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimizes Space in Dense Wire Ducts:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA rugged, flexible outer sheath encapsulates the internal conductor bundles. This slim cross-section allows tight bends inside overcrowded control cabinets without crimping conductors or degrading signal pathways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable assembly suitable for 1756 discrete digital I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Rockwell Automation builds the 1492-ACABLE025UD specifically with internal shielding and conductor arrangements optimized for low-voltage analog, RTD, and thermocouple input signals. Digital signals require unshielded or differently bundled digital cable counterparts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo you ship this item in authentic, factory-sealed condition?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the 1492-ACABLE025UD as a 100% brand new, original manufacturer product in its pristine, original packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this 2.5-meter cable require additional external shielding considerations during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable provides integral shield protection throughout its 2.5-meter length. Technicians must connect the cable’s pre-designated shield drain wire directly to a clean instrument ground point according to standard ControlLogix installation instructions to prevent ground loop noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53481273131192,"sku":"1492-ACABLE025UD","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1492-ACABLE025UD.jpg?v=1779154633","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-1492-acable025ud-1492-pre-wired-analog-cable-assembly","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}