{"product_id":"allen-bradley-1492-aifm8-3-1492-digital-analog-wiring-system-interface-module","title":"Allen-Bradley 1492-AIFM8-3 1492 Digital\/Analog Wiring System Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1792-AIFM8-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density interface for digital and analog programmable controller wiring systems. This module streamlines the connection between field devices and I\/O modules, replacing traditional point-to-point wiring with an organized, pre-tested terminal solution. It supports 8-channel input or output configurations, utilizing 3 terminals per channel to facilitate power, signal, and return connections. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Factory Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, ensuring maximum signal integrity for your control architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFeed-Through Interface Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8-Channel (Input or Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 Terminals per Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 132 V AC\/DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Current (Per Circuit)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Current (Total Module)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (LxWxH)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.96 cm x 11 cm x 8.30 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital and Analog PLC I\/O Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDrastic Reduction in Wiring Errors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1492-AIFM8-3 eliminates the complexity of manually landing hundreds of wires. By using pre-wired cables to connect the module to the PLC, you eliminate common cross-wiring mistakes and significantly accelerate commissioning times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving 3-Terminal Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides 3 dedicated terminals for every channel. This allows for direct landing of 3-wire sensors or actuators without requiring additional distribution terminal blocks, saving critical horizontal space on the DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach circuit supports up to 2 Amps, with a total module capacity of 12 Amps. This robust current rating enables the module to handle power-heavy solenoids and industrial actuators without the risk of thermal failure or trace degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Voltage Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe wide 0-132V AC\/DC operating range allows engineers to standardize on a single interface module for both low-voltage DC signals and high-voltage AC control loops, simplifying inventory management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe organized layout and clearly marked terminal points facilitate rapid multi-meter probing. Technicians identify and isolate field-side faults quickly without tracing wires through congested wire ducts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1492-AIFM8-3 support analog signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While often used for digital I\/O, the feed-through design maintains signal transparency for analog 4-20mA or 0-10V loops. Ensure you use shielded cables to the PLC to prevent noise interference in sensitive analog applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for 16-channel systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1492-AIFM8-3 specifically handles 8 channels with 3 terminals each. If your application requires 16 channels, you must either install two 1492-AIFM8-3 modules or select a high-density version from the 1492-AIFM series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting orientation do you recommend?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can mount the module horizontally or vertically on a standard 35mm DIN rail. The 8.30 cm height profile ensures compatibility with standard-depth industrial enclosures while leaving sufficient room for wire bend radiuses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product brand new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this 1492-AIFM8-3 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand ships in its original Allen-Bradley factory packaging. We do not sell refurbished or \"New-Old-Stock\" with damaged terminals; you receive a factory-fresh component.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53447239729336,"sku":"1492-AIFM8-3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1492-AIFM8-3.jpg?v=1778230858","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-1492-aifm8-3-1492-digital-analog-wiring-system-interface-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}