{"product_id":"allen-bradley-150-f60nbd-smc-flex-solid-state-soft-starter","title":"Allen-Bradley 150-F60NBD SMC-Flex Solid-State Soft Starter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e150-F60NBD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance smart motor controller within the Allen-Bradley SMC-Flex family. This solid-state starter provides modular, flexible control for three-phase squirrel-cage induction motors, specifically targeting applications up to 40 HP at 460V AC. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal stock, ensuring the highest level of component integrity for demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecific Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e150\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBulletin Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSMC-Flex Solid-State Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eF60\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Amperes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Type (Panel Mount)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInput Line Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 to 480 V AC, 3-phase, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControl Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 to 240 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eController Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolid-state \/ Digital\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMotor Power (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 HP @ 460 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–480 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-5 to 50 °C (23 to 122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDegree 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Altitude\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 m (approx. 6560 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.90 kg (13.00 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Bypass Contactor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 150-F60NBD incorporates internal bypass power poles. Once the motor reaches full speed, the unit automatically switches to the bypass, significantly reducing heat generation and eliminating the need for oversized cooling systems in the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSelectable Control Modes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis starter offers nine standard start modes, including Soft Start, Current Limit, and Full Voltage. This versatility allows engineers to eliminate mechanical shock on belts, gears, and couplings by tailoring the torque curve to specific load profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe built-in electronic motor overload protection monitors phase imbalance and stall conditions. This proactive sensing shuts down the system before motor windings suffer permanent thermal damage, reducing unplanned downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Open-Type Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe panel-mount configuration maximizes cabinet interior space. The design allows for vertical mounting, which utilizes natural convection to maintain optimal operating temperatures even in high-density electrical enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle the initial torque requirements for high-friction loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the \"Kickstart\" feature. The 150-F60NBD provides a boost pulse at the beginning of the start sequence to break static friction, transitioning smoothly into the programmed ramp-up time once the load moves.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a separate motor protection relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The SMC-Flex integrates full electronic overload protection. You configure the trip class (10, 15, 20, or 30) directly through the digital interface, which eliminates the cost and wiring of external thermal relays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary considerations for mounting at high altitudes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the unit operates at full rating up to 2000 meters, you must apply de-rating factors if installing the starter above this elevation. High altitudes reduce air density, which impairs the heat dissipation of the power SCRs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 150-F60NBD for controlled braking?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports \"SMB\" (Smart Motor Braking) and \"Accu-Stop.\" These features use controlled DC injection to bring high-inertia loads to a standstill faster than a traditional coast-to-stop, enhancing facility safety and cycle times.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53410946515128,"sku":"150-F60NBD","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/150-F60NBD.jpg?v=1777278969","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-150-f60nbd-smc-flex-solid-state-soft-starter","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}