{"product_id":"allen-bradley-1715-tasif16-redundant-i-o-termination-assembly","title":"Allen Bradley 1715-TASIF16 Redundant I\/O Termination Assembly","description":"\u003cp\u003eConfigured for high-density signal distribution in 1715-IF16 Analog Input systems, the \u003cstrong\u003eAllen Bradley 1715-TASIF16\u003c\/strong\u003e (\u003cstrong\u003e1715-TASIF16\u003c\/strong\u003e Redundant I\/O Termination Assembly) provides direct physical and electrical execution of field-to-module wiring interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1715-TASIF16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard assembly weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 1715 I\/O system footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial rated range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive signal distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Analog Inputs (Simplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 1715-TASIF16 assembly manages backplane bus communication velocity by providing a dedicated termination point for the 1715-IF16 analog input module. The assembly maintains deterministic signal path integrity, supporting I\/O density scaling within the 1715 redundancy architecture. Firmware flash compatibility is intrinsically managed by the host I\/O module, ensuring that analog signals are digitized and mapped according to the configured scan rate of the controller. The assembly ensures galvanic integrity of the input loops, preventing common-mode interference from propagating across the backplane bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1715-TASIF16 assembly support hot-swapping of the attached 1715-IF16 module?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The termination assembly is designed to allow for the removal and replacement of the I\/O module without disconnecting field wiring, provided the system logic is configured for hot-swap operations.\u003c\/p\u003e\n\u003cp\u003eQ: How is redundancy managed by this specific termination assembly?\u003c\/p\u003e\n\u003cp\u003eA: The 1715-TASIF16 is engineered to serve the 1715-IF16 module in a simplex configuration. When utilized within a redundant system chassis, it serves as the physical interface layer for the primary signal paths, supporting the overall redundancy scheme of the 1715 I\/O platform.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Mounting:\u003c\/strong\u003e Secure the termination assembly onto the system backplane or chassis rail. Ensure the mechanical alignment pins are fully seated to maintain backplane connector alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Terminate field signal wiring according to the loop diagrams. Use shielded twisted-pair cabling and terminate shields at the designated ground bar on the assembly to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating:\u003c\/strong\u003e Insert the 1715-IF16 module into the termination assembly. Apply firm, even pressure to ensure the multi-pin connector is fully mated to the backplane interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Specifications:\u003c\/strong\u003e Tighten all terminal screws to the specified torque rating to ensure a gas-tight electrical connection and prevent oxidation over the service life of the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Verification:\u003c\/strong\u003e Prior to applying field power, measure the resistance of each loop to ground to ensure no shorts or ground faults exist in the field wiring.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53523366215864,"sku":"1715-TASIF16","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1715-TASIF16.jpg?v=1780025656","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-1715-tasif16-redundant-i-o-termination-assembly","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}