{"product_id":"allen-bradley-1734-ib8s-point-guard-i-o-safety-module","title":"Allen Bradley 1734-IB8S POINT Guard I\/O Safety Module","description":"\u003cp\u003eConfigured for safety-rated signal acquisition in POINT I\/O networks, the \u003cstrong\u003eAllen Bradley 1734-IB8S\u003c\/strong\u003e (\u003cstrong\u003e1734-IB8S\u003c\/strong\u003e) Safety Module provides direct physical\/electrical execution of safety-critical input and output monitoring within industrial control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-IB8S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.09 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 (Current Sinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4 (Current Sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReaction Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 16.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSafety Integrity and Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1734-IB8S\u003c\/strong\u003e is designed to meet strict SIL3 certification requirements, ensuring robust performance in safety-instrumented systems. The module utilizes a safety-rated architecture to execute fail-safe state transitions upon detection of internal hardware diagnostics or loss of communication with the safety controller. Its design incorporates galvanic isolation between field inputs and backplane circuitry to prevent common-mode electrical faults. The safety-rated outputs are capable of sourcing current while maintaining diagnostic coverage, allowing the safety controller to verify the integrity of the connected final control elements and ensure immediate transition to a safe state when required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while the safety network is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. Due to the safety-critical nature of the hardware, hot-swapping is not permitted. The safety system must be de-energized to prevent unintended safety trips or faults resulting from transient electrical noise during module insertion or removal.\u003c\/p\u003e\n\u003cp\u003eQ: How is the off-state voltage threshold verified for safety compliance?\u003c\/p\u003e\n\u003cp\u003eA: The input circuitry is rated to recognize a maximum off-state voltage of 5 VDC and a current of 1.3 mA. Field signals exceeding these thresholds will be registered as an on-state, which must be accounted for during the selection of field sensors to prevent unsafe operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module on a standard 35 mm DIN-rail, ensuring proper alignment with the mounting base to maintain mechanical stability and electrical contact.\u003c\/li\u003e\n\u003cli\u003eTerminate all safety-rated field wiring according to the provided wiring diagram, ensuring correct polarity for sinking inputs and sourcing outputs.\u003c\/li\u003e\n\u003cli\u003eUse only shielded, low-capacitance cable for safety inputs to minimize signal corruption and to meet Electromagnetic Compatibility (EMC) requirements.\u003c\/li\u003e\n\u003cli\u003eVerify that the cable shields are grounded at the point of origin or the system cabinet as specified in the safety manual to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eEnsure the input current remains above the 3.3 mA minimum on-state threshold to maintain a valid signal status in the safety controller logic.\u003c\/li\u003e\n\u003cli\u003eUpon initial power-up, perform a full safety system validation test to verify that all inputs and outputs correspond correctly to the programmed logic and that no fault bits are present.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53514801447096,"sku":"1734-IB8S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-IB8S1.jpg?v=1779852025","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-1734-ib8s-point-guard-i-o-safety-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}