{"product_id":"allen-bradley-1734-ie8c-point-i-o-8-channel-analog-current-input-module","title":"Allen-Bradley 1734-IE8C POINT I\/O 8-Channel Analog Current Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1734-IE8C functions as a high-density analog current input module within the POINT I\/O distributed hardware platform. This compact module digitizes raw 4–20 mA or 0–20 mA current loops from field transmitters, including pressure sensors, flow meters, and temperature transducers, converting them into precise signed integer data values for the host controller. We distribute this critical network slice exclusively in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed condition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure exact out-of-the-box calibration, prevent channel-to-channel crosstalk, and maintain uninterrupted signal tracking across your remote I\/O nodes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRockwell Automation \/ Allen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1734-IE8C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e612598347872\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O 1734 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Analog Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Single-Ended Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current Range Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA or 0 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Conversion Topology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSigma-Delta Converter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNative Data Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSigned Integer Format\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Absolute Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1% Full Scale at 25°C (77°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA at 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 Watts Maximum at 28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Keyswitch Position\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePosition 3 Setup Location\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Shock Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 G Peak Acceleration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +55°C (-4°F to 131°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Assembly Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 lbs (0.11 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximizes Channel Density in Cramped Enclosures:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module packs eight independent analog input channels into an ultra-slim, 0.25 lbs physical footprint. This high-density arrangement allows control engineers to expand analog instrumentation counts inside small remote terminal boxes and machine-mount junction panels without upgrading enclosure sizes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilters Out Severe Plant-Floor Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard Sigma-Delta conversion engine oversamples the incoming current waves, filtering out high-frequency electrical harmonics and common-mode noise generated by nearby variable frequency drives (VFDs). This processing delivers an absolute accuracy of 0.1% full scale directly to your master control registers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLowers Panel Power and Cooling Burden:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe optimized circuit design draws a minimal 75 mA from the 5V DC POINTBus backplane while limiting internal power dissipation to 0.6 Watts at 28.8V DC. This low thermal output prevents localized heat pockets within tightly packed DIN-rail assemblies, extending the operating life of adjacent communications adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGuarantees Mistake-Proof Field Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module chassis keys directly into Position 3 on standard 1734-TB terminal bases. This mechanical interlock blocks installers from accidentally sliding a digital or high-voltage module into an analog slot during rapid field maintenance, preventing component over-voltage destruction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module supply loop power directly to 2-wire field transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-IE8C measures incoming current signals but does not distribute 24V DC loop power to active field devices. You must route your 2-wire transmitters through an external bulk power source or utilize a 1734-FPD Field Power Distributor module to energize the current loops before tying them into the module terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this analog input card an authentic factory-new component or a cleaned surplus unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this product is 100% brand new, factory-original, and completely unused automation stock. It ships inside its authentic manufacturer packaging with unmarred backplane blade links, intact factory serialization labels, and untouched calibration parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I scale the 4-20mA signal into engineering units directly on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-IE8C transmits data to the processor exclusively in signed integer format. You handle final engineering unit scaling—such as converting raw counts to PSI, GPM, or degrees—within your Logix5000 controller software program using the scaling (SCL) instruction or simple mathematical rungs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53478671483064,"sku":"1734-IE8C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1734-IE8C1.jpg?v=1779097641","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-1734-ie8c-point-i-o-8-channel-analog-current-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}