{"product_id":"allen-bradley-1747-c13-slc-500-dh-485-operating-system-programming-cable","title":"Allen-Bradley 1747-C13 SLC 500 DH-485 Operating System Programming Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1747-C13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized interconnect cable for the SLC 500 modular hardware platform. This 3-foot (0.9 meter) cable facilitates the physical link between an SLC 500 processor (via the RJ45 port) and a 1747-PIC Personal Computer Interface Converter or a 1747-UIC USB-to-DH-485 interface. It enables critical functions such as program uploads, downloads, and real-time data monitoring over the DH-485 network. We provide this cable as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal stock to ensure error-free data transmission and a secure mechanical fit.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1747-C13 meets the specific electrical requirements for DH-485 signaling:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1747-C13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDH-485 Programming \/ Operating System Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8-Pin RJ45 to 8-Pin RJ45 (Shielded)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 feet (0.91 meters)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSLC 500, SLC 5\/01, 5\/02, 5\/03 Processors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1747-PIC, 1747-UIC, 1747-AIC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 lbs (0.1 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielded Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1747-C13 utilizes high-quality shielding to protect data packets from electromagnetic interference (EMI) commonly found in industrial environments. This shielding prevents communication timeouts and checksum errors during critical firmware or program transfers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision RJ45 Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe factory-molded RJ45 connectors ensure a tight, low-resistance connection with the processor port. This eliminates the intermittent connectivity issues often associated with generic or hand-crimped network cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Portability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3-foot length provides the ideal span for connecting a laptop or interface box to a PLC rack within a control cabinet. This keeps the workspace organized and minimizes the risk of cable snagging during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Pinout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1747-C13 guarantees the correct proprietary pinout required by Allen-Bradley hardware. This prevents the potential short-circuits or hardware damage that can occur when using standard Ethernet patch cables in DH-485 ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use a standard Ethernet cable instead of the 1747-C13?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. While the connectors look identical to RJ45 Ethernet, the pinout and electrical signals for DH-485 differ significantly. Using a standard Ethernet cable can damage the processor's communication port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this cable connect directly to a PC's serial port?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 1747-C13 must connect to a converter, such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-UIC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(USB) or the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-PIC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Serial), which then interfaces with your computer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this cable compatible with the SLC 5\/04 or 5\/05 processors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the 1747-C13 can physically plug into the DH-485 port of a 5\/03, it is primarily used for the SLC 5\/01 and 5\/02. The SLC 5\/05 uses standard Ethernet (RJ45), but for its specific communication protocols, always refer to the hardware manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is \"Brand New\" quality important for a simple cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed cables often suffer from weakened internal copper strands or worn locking tabs. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1747-C13 ensures the locking clip stays secure and the internal resistance remains within factory tolerances for stable communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53286140870840,"sku":"1747-C13","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1747-C13.jpg?v=1775815126","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-1747-c13-slc-500-dh-485-operating-system-programming-cable","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}