{"product_id":"allen-bradley-1756-ir12-controllogix-12-channel-rtd-analog-input-module","title":"Allen-Bradley 1756-IR12 ControlLogix 12-Channel RTD Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IR12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-density temperature sensing for the ControlLogix platform. This module interfaces directly with up to 12 3-wire Resistance Temperature Detectors (RTDs) or other resistance-based sensors. It converts low-level analog resistance signals into 24-bit digital data for precise process control in chemical, power, and food processing industries. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring factory-sealed integrity for your high-availability ControlLogix chassis.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Non-isolated Channels (3-wire)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResistance Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–500 Ω, 2–1000 Ω, 4–2000 Ω, 8–4000 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw (5.1V DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw (24V DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0° to 60°C (32° to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Display\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated LED Diagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Thermal Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 12-channel architecture allows for extensive temperature monitoring across a single chassis slot. This reduces the total number of modules required in large-scale thermal applications, saving valuable backplane space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior 24-Bit Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 24-bit resolution detects minute resistance changes. This sensitivity ensures accurate temperature feedback even in applications with very narrow process windows, improving overall product quality and safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLead-Wire Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module specifically supports 3-wire RTD configurations. It automatically compensates for the resistance of the lead wires, ensuring that the sensor cable length does not skew your temperature readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 250V continuous isolation voltage protects the controller logic from field-side electrical surges. This isolation barrier prevents ground loops and minimizes the impact of electromagnetic interference (EMI) on the analog signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1756-IR12 support 2-wire or 4-wire RTDs?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module primarily targets 3-wire RTD connections to utilize its internal compensation circuitry. While you can wire other types by following specific terminal jumpering procedures, 3-wire sensors provide the best balance of accuracy and lead-wire compensation for this hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat resistance ranges does the module support?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1756-IR12 offers four user-selectable ranges: 1–500 Ω, 2–1000 Ω, 4–2000 Ω, and 8–4000 Ω. This allows you to interface with a wide variety of platinum, nickel, copper, or moly RTD elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the Status LEDs assist in troubleshooting?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a front-panel display that indicates the health of the module and the status of individual channels. If a sensor wire breaks or a channel exceeds its range, the LED diagnostics alert maintenance personnel immediately, slashing mean time to repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific Removable Terminal Block (RTB)?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. You must use a compatible 36-pin RTB (such as the 1756-TBCH or 1756-TBSH) to connect field wiring. We recommend using shielded twisted-pair cable to maintain the high signal-to-noise ratio provided by the 24-bit converter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53414101352632,"sku":"1756-IR12","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1756-IR12.jpg?v=1777364912","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-1756-ir12-controllogix-12-channel-rtd-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}