{"product_id":"allen-bradley-1756-oa16i-controllogix-digital-ac-output-module","title":"Allen-Bradley 1756-OA16I ControlLogix Digital AC Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-OA16I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density discrete output solution for the ControlLogix platform. This module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 individually isolated outputs\u003c\/strong\u003e, providing superior electrical separation between channels to prevent ground loops and cross-talk in complex industrial circuits. It interfaces directly with field devices such as motor starters, solenoid valves, and indicators operating within a wide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74-265 VAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erange. We guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand ships in original factory packaging to ensure maximum lifecycle reliability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table outlines the critical electrical and physical parameters for the 1756-OA16I:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Individually Isolated Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e74–265 VAC (47–63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current (5.1V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e225 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Current per Point\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A @ 30 °C (Linear derating to 1 A @ 60 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Current per Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A @ 30 °C (Linear derating to 4 A @ 60 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 Watts (Max @ 60 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOff-State Leakage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 mA per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Delay (OFF to ON)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.3 ms @ 60 Hz \/ 11 ms @ 50 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible RTB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-TBCH or 1756-TBS6H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard grouped modules, the 1756-OA16I isolates every single point. This design allows you to mix different AC phases or separate power sources on the same module without risking catastrophic hardware failure or signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module manages power dissipation effectively, maintaining 5.5 Watts at peak load. This reduces the heat load within your PLC enclosure, extending the lifespan of neighboring processors and communication bridges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Fault Recovery:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBCH (36-pin) Removable Terminal Block\u003c\/strong\u003e, maintenance teams can swap modules in seconds without disconnecting individual field wires. This minimizes \"Mean Time to Repair\" (MTTR) during critical system outages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Load Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting up to 2 Amps per point at 30 °C, this module handles high-inrush inductive loads common in heavy-duty manufacturing environments, eliminating the need for interposing relays in many applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a specific Removable Terminal Block (RTB)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The 1756-OA16I requires either the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBCH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Cage clamp) or the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBS6H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Spring clamp). You must purchase these separately as they do not ship with the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the 1756-OA16I for DC voltage applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This module utilizes Triac outputs specifically designed for AC switching. Attempting to switch DC loads will result in the output failing to turn off once energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if the internal temperature exceeds 60 °C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module requires linear derating. Operating beyond 60 °C (140 °F) risks hardware damage. We recommend maintaining proper enclosure ventilation to keep the continuous current within the specified 4 A module limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this unit a factory-refurbished part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original Allen-Bradley hardware\u003c\/strong\u003e. Each unit comes with the original serial number and factory seals intact for full traceability and warranty support.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53286050529464,"sku":"1756-OA16I","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1756-OA16I.jpg?v=1775812534","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-1756-oa16i-controllogix-digital-ac-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}