{"product_id":"allen-bradley-1794-vhsc-flex-i-o-very-high-speed-counter-module","title":"Allen-Bradley 1794-VHSC Flex I\/O Very High Speed Counter Module","description":"\u003cp\u003eConfigured for high-frequency pulse counting in Flex I\/O control networks, the \u003cstrong\u003eAllen-Bradley 1794-VHSC\u003c\/strong\u003e (\u003cstrong\u003e1794-VHSC\u003c\/strong\u003e Very High Speed Counter Module) provides direct physical\/electrical execution. The module interfaces with external high-speed signal sources to perform real-time counting operations, utilizing two isolated output groups to provide feedback or control responses based on configured count thresholds.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-VHSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 lbs (0.11 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Flex I\/O Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.0 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 31 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 1794-VHSC module integrates into Flex I\/O systems, requiring stable backplane bus communication to maintain synchronization between the high-speed counter registers and the primary controller. Due to the high-speed nature of the input signals, users must ensure the backplane communication velocity remains within defined limits to prevent data throughput bottlenecks. Firmware flash compatibility should be verified against the specific Flex I\/O adapter module in use to ensure proper module recognition and register mapping during the initialization phase.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1794-VHSC support hot-swapping in a Flex I\/O rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 1794-VHSC is designed for removal and insertion under power (RIUP) when mounted on a compatible Flex I\/O terminal base. Ensure the surrounding modules and base are secure before operation.\u003c\/p\u003e\n\u003cp\u003eQ: What are the off-state requirements for the inputs?\u003c\/p\u003e\n\u003cp\u003eA: To ensure the module correctly registers an off-state signal, the input voltage must remain below 1.8 VDC with a leakage current of less than 0.25 mA. Exceeding these values may result in indeterminate logic states.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Base Mounting\u003c\/strong\u003e: Secure the module onto a compatible Flex I\/O terminal base. Ensure the mechanical locking mechanism is fully engaged to maintain reliable electrical contact with the backplane connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Wiring\u003c\/strong\u003e: Use shielded twisted-pair cabling for high-speed pulse inputs to mitigate electromagnetic interference (EMI). Terminate the cable shield at a central grounding point to minimize ground potential differences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput\/Output Isolation\u003c\/strong\u003e: Maintain physical separation between high-speed input wiring and output load wiring to prevent crosstalk and noise injection into the counter circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e: Ensure the installation environment is free from conductive dust and excessive moisture. Although the module is rated for industrial use, it must be housed within an enclosure that provides adequate protection against environmental contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53533593698488,"sku":"1794-VHSC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1794-VHSC.jpg?v=1780285323","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-1794-vhsc-flex-i-o-very-high-speed-counter-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}