{"product_id":"allen-bradley-20-750-s-powerflex-drive-guard-board","title":"Allen-Bradley 20-750-S PowerFlex Drive Guard Board","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 20-750-S\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e20-750-S\u003c\/strong\u003e Drive Guard Board, operates as a dedicated hardware component for safe torque off (STO) execution within PowerFlex 750 series drive platforms. This module provides direct physical\/electrical execution by interrupting the gate drive signals to the inverter, preventing the power stage from generating torque-producing motor current when the 24 VDC safety input is de-energized.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e20-750-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 750 option slot form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard (drive-enclosure dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e90 A max (drive stage dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Function\u003c\/td\u003e\n\u003ctd\u003eSafe Torque Off (STO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC and Drive Deterministic Network Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 20-750-S Drive Guard Board integrates into the PowerFlex 750 architecture to facilitate fail-safe state execution during machine emergency stops. By bypassing the control logic and directly interfacing with the inverter gate drive circuitry, the module ensures that the motor ceases torque production regardless of the software state in the host PLC. Integration of this board requires strict adherence to firmware flash compatibility requirements between the drive and the safety controller to ensure that the STO status is accurately reported back through the network protocol, thereby maintaining the deterministic timing necessary for integrated safety systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 20-750-S module require external power for its safety function?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module requires a 24 VDC signal to maintain the drive in a run-enabled state. If the 24 VDC signal is removed, the Safe Torque Off function is triggered immediately.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while the PowerFlex 750 drive is under load?\u003c\/p\u003e\n\u003cp\u003eA: No. Any installation or removal of the Drive Guard Board must be performed while the drive is completely de-energized and verified via the lockout\/tagout procedure to prevent unexpected operation or hardware damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Alignment:\u003c\/strong\u003e Insert the Drive Guard Board into the designated safety slot within the PowerFlex 750 drive. Ensure the module is fully seated so that the internal connection pins engage with the drive backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Isolation:\u003c\/strong\u003e Route the 24 VDC safety input wiring separately from high-voltage motor cabling to avoid induced noise. Use high-quality, insulated conductors to maintain the integrity of the safety circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Verification:\u003c\/strong\u003e Post-installation, perform a functional safety test by initiating an STO request via the 24 VDC supply. Verify that the drive display reflects the safety state and that the motor output is disabled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Integrity:\u003c\/strong\u003e Ensure that the drive enclosure maintains its IP rating following the installation of the safety board. Dust and moisture ingress into the option slot can lead to corrosion of the communication pins, potentially causing intermittent safety faults.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53546617995448,"sku":"20-750-S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/20-750-S.jpg?v=1780566510","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-20-750-s-powerflex-drive-guard-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}