{"product_id":"allen-bradley-2094-bc01-m01-m-kinetix-6200-integrated-axis-module","title":"Allen-Bradley 2094-BC01-M01-M Kinetix 6200 Integrated Axis Module","description":"\u003cp\u003eConfigured for precision motion control in Kinetix 6200 platforms, the \u003cstrong\u003eAllen-Bradley 2094-BC01-M01-M\u003c\/strong\u003e (\u003cstrong\u003e2094-BC01-M01-M\u003c\/strong\u003e Integrated Axis Module) provides direct physical and electrical execution of multi-axis servo motor regulation across high-speed industrial networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2094-BC01-M01-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSubject to manufacturing batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Kinetix 6200 drive frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e460 VAC (3-phase 360-480 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Capacitance\u003c\/td\u003e\n\u003ctd\u003e4585 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus and Network Communication\u003c\/h3\u003e\n\u003cp\u003eThe 2094-BC01-M01-M utilizes the Kinetix backplane bus communication to synchronize drive commands and diagnostic feedback with the master controller. Integration into industrial control systems requires strict adherence to firmware flash compatibility requirements to ensure deterministic network performance over EtherNet\/IP or SERCOS interfaces. The module supports I\/O density scaling within the drive chassis, allowing for complex multi-axis synchronization while maintaining the necessary bus timing parameters required for high-velocity motion execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 2094-BC01-M01-M support hot-swapping within the drive system?\u003c\/p\u003e\n\u003cp\u003eA: No. The Integrated Axis Module (IAM) involves high-voltage DC bus connections and multi-phase power distribution. The drive must be isolated, and the DC bus must be verified as fully discharged before removal or installation to prevent catastrophic hardware failure or electrical hazard.\u003c\/p\u003e\n\u003cp\u003eQ: How is the drive performance validated during firmware updates?\u003c\/p\u003e\n\u003cp\u003eA: Drive firmware updates must be performed via the Motion Analyzer or Studio 5000 environment. After flashing, the drive must perform a power cycle to re-initialize the internal gate drive logic and confirm the stability of the backplane communication link.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e The 2094-BC01-M01-M relies on forced air cooling. Maintain the minimum clearance requirements above and below the drive unit as specified in the installation manual. Ensure the cabinet fans are operational to prevent localized overheating that may trigger thermal trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e Verify that the 3-phase AC input is within the 360-480 VAC range. Proper shielding of motor leads is required to mitigate electromagnetic interference, and the drive chassis must be bonded to the cabinet's protective earth ground with a low-impedance connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Routing:\u003c\/strong\u003e Separate power cables from encoder feedback and communication signal cables to avoid induced noise on the feedback loops. Ensure all cable shields are terminated at the designated drive shield clamps to maintain electromagnetic compatibility (EMC) compliance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53548961628344,"sku":"2094-BC01-M01-M","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2094-BC01-M01-M.jpg?v=1780622994","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-2094-bc01-m01-m-kinetix-6200-integrated-axis-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}