{"product_id":"allen-bradley-2094-bc02-m02-s-integrated-axis-module","title":"Allen-Bradley 2094-BC02-M02-S Integrated Axis Module","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2094-BC02-M02-S\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2094-BC02-M02-S\u003c\/strong\u003e Integrated Axis Module, operates as a dedicated hardware component for multi-axis motion control and power conversion within Kinetix 6000 drive systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2094-BC02-M02-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\/Global\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Kinetix 6000 IAM profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on bus loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Class\u003c\/td\u003e\n\u003ctd\u003e400V-Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage Range\u003c\/td\u003e\n\u003ctd\u003e360-480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e324-528V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input (Common Bus)\u003c\/td\u003e\n\u003ctd\u003e458-747V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Loss Ride-Through\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Overvoltage Trip\u003c\/td\u003e\n\u003ctd\u003e825V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Undervoltage Trip\u003c\/td\u003e\n\u003ctd\u003e275V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt Resistor\u003c\/td\u003e\n\u003ctd\u003e115 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 2094-BC02-M02-S utilizes the Kinetix 6000 backplane bus architecture to maintain deterministic communication across the motion control network. Firmware flash compatibility is mandatory for integration with existing Kinetix 6000 drive groups; users must ensure the motion controller revision supports the IAM module's specific firmware build. The module manages I\/O density scaling through its integrated axis interface, allowing for high-speed synchronization of motor feedback and command signals. Proper configuration of the bus communication velocity is required to prevent jitter in high-precision motion loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary considerations for the Safe Torque Off (STO) feature on this module?\u003c\/p\u003e\n\u003cp\u003eA: The STO feature requires dual-channel input to reach the intended safety integrity level. Ensure that external contactors or safety relays are wired to remove power from the gate drive circuits without cycling the main AC input.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module react to a momentary power loss below the 20 ms ride-through limit?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed to maintain control logic and bus synchronization for up to 20 ms. If the input voltage remains below the operational threshold beyond this duration, the system will initiate a controlled shutdown to prevent unexpected axis movement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMounting: Install the module on a grounded panel using the provided mounting hardware. Ensure the chassis maintains adequate clearance for heat sink airflow.\u003c\/li\u003e\n\u003cli\u003eGrounding: Connect the module chassis to a low-impedance earth ground to satisfy high-frequency noise suppression requirements.\u003c\/li\u003e\n\u003cli\u003eWiring: Use shielded twisted-pair cables for signal lines and appropriate gauge copper wire for power inputs. Maintain separation between power and signal cabling to prevent electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eShunt Resistor: Verify the load resistance requirements for the application; the internal 115 Ohms resistor is intended for standard braking duty cycles.\u003c\/li\u003e\n\u003cli\u003eShielding: Ensure all cable shields are terminated at the designated ground terminals on the module or drive chassis to ensure effective EMI protection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53559395582136,"sku":"2094-BC02-M02-S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2094-BC02-M02-S.jpg?v=1780889972","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-2094-bc02-m02-s-integrated-axis-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}