{"product_id":"allen-bradley-2094-bc04-m03-s-integrated-axis-power-module","title":"Allen-Bradley 2094-BC04-M03-S Integrated Axis Power Module","description":"\u003cp\u003eConfigured for multi-axis motion control in Kinetix 6000 platforms, the \u003cstrong\u003eAllen-Bradley 2094-BC04-M03-S\u003c\/strong\u003e (\u003cstrong\u003e2094-BC04-M03-S\u003c\/strong\u003e Integrated Axis Module) provides direct physical execution of high-speed velocity and current loop regulation. This module functions as the primary converter and inverter stage for 400 Volt class three-phase AC input systems, facilitating synchronized motor control through advanced pulse-width modulation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2094-BC04-M03-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e94 W to 255 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e28 kW (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e30 A (Inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e400\/460 VAC (324-528 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWM Frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 2094-BC04-M03-S requires precise integration within the Kinetix 6000 bus topology to maintain deterministic performance. As the leftmost module on the power rail, it manages the primary AC input conversion and common bus distribution. The velocity loop bandwidth of 500 Hz and current loop bandwidth of 1300 Hz necessitate low-latency feedback connections to ensure stable motion profiles. Firmware flash compatibility is critical; users must ensure the module firmware is aligned with the motion controller's executive software version to avoid register mapping errors or control loop instability during axis coordination.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 2094-BC04-M03-S support hot-swapping under load?\u003c\/p\u003e\n\u003cp\u003eA: No. The power module must be disconnected from the AC input and the common bus must be verified as fully discharged before removal. Failure to dissipate bus energy prior to unseating the module can lead to catastrophic damage to the power rail connectors and internal power semiconductors.\u003c\/p\u003e\n\u003cp\u003eQ: How should the internal shunt resistor be configured for high-inertia deceleration loads?\u003c\/p\u003e\n\u003cp\u003eA: The internal shunt handles 200 W continuous power. For applications exceeding this thermal threshold during deceleration, an external shunt resistor must be connected to the designated terminals to prevent over-voltage faults on the DC bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Stability\u003c\/strong\u003e: The module must be installed at the leftmost position of the power rail. Ensure the power rail is securely fastened to a grounded, conductive subpanel to provide a low-impedance path for high-frequency noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Maintain a minimum vertical clearance of 100 mm above and below the module to allow for proper airflow through the heat sink. Ensure ambient operating temperature does not exceed 50 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding\u003c\/strong\u003e: Shielded motor cables must be bonded to the module's grounding lug with a 360-degree contact to minimize radiated electromagnetic interference. Ensure the common bus return is properly referenced to earth ground in accordance with local electrical codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Constraints\u003c\/strong\u003e: Use copper conductors rated for 75 deg C or higher. Ensure all input\/output terminal screws are torqued to the specified value to prevent resistive heating at the connection point.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53541891375288,"sku":"2094-BC04-M03-S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2094-BC04-M03-S.jpg?v=1780478007","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-2094-bc04-m03-s-integrated-axis-power-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}