{"product_id":"allen-bradley-2094-bm01-s-kinetix-6000-axis-module","title":"Allen-Bradley 2094-BM01-S Kinetix 6000 Axis Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2094-BM01-S\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2094-BM01-S\u003c\/strong\u003e Axis Module, operates as a dedicated hardware component for servo motor control and motion trajectory execution within Kinetix 6000 multi-axis drive platforms. This module provides high-speed current regulation and pulse-width modulation (PWM) switching to manage motor torque and velocity loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2094-BM01-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Kinetix 6000 Single-Wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on operational duty cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e650 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous RMS Current\u003c\/td\u003e\n\u003ctd\u003e6.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Power Output\u003c\/td\u003e\n\u003ctd\u003e3.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWM Frequency\u003c\/td\u003e\n\u003ctd\u003e8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency Rating\u003c\/td\u003e\n\u003ctd\u003e98 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 2094-BM01-S facilitates high-speed motion control through deterministic network integration within the Kinetix 6000 backplane architecture. The module supports precise synchronization for motion profiles, minimizing latency between command generation and physical actuator execution. Firmware flash compatibility must be validated against the system controller version prior to deployment to ensure network handshake integrity. High-density I\/O configurations require careful attention to the backplane bus communication velocity to avoid signal timing deviations during concurrent multi-axis operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the internal 115 Ohms shunt resistor?\u003c\/p\u003e\n\u003cp\u003eA: The internal shunt resistor is utilized to dissipate excess regenerative energy generated by the motor during deceleration phases, preventing DC bus overvoltage conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 2094-BM01-S compatible with standard PLC backplane hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: No. The axis module must not be removed or inserted while the Kinetix 6000 DC bus is energized, as this can cause electrical arcing and damage to the backplane communication pins.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mounting\u003c\/strong\u003e: Install the module onto the Kinetix 6000 interface module. Ensure the locking tab is fully engaged to provide mechanical stability and ground continuity through the chassis rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements\u003c\/strong\u003e: Secure the chassis to a verified protective earth ground point. Use high-frequency braid or short, low-impedance cables to connect the drive system to the cabinet ground bus to minimize common-mode electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Separate high-voltage motor power leads from low-voltage control and feedback signals to prevent induced noise in the encoder or resolver loops. Use shielded, twisted-pair cabling for all feedback interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling\u003c\/strong\u003e: Maintain at least 50 mm of unobstructed vertical clearance above and below the module to ensure convection heat dissipation. Avoid installing the module in environments with high particulate concentrations to prevent fan intake blockage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53559503716536,"sku":"2094-BM01-S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2094-BM02-S_b3253d61-8d88-49e5-af15-07d7ea7061f6.jpg?v=1780891084","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-2094-bm01-s-kinetix-6000-axis-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}