{"product_id":"allen-bradley-2094-bm02-s-kinetix-6000-axis-module","title":"Allen-Bradley 2094-BM02-S Kinetix 6000 Axis Module","description":"\u003cp\u003eConfigured for high-speed motion control in Kinetix 6000 integrated motion platforms, the \u003cstrong\u003eAllen-Bradley 2094-BM02-S\u003c\/strong\u003e (\u003cstrong\u003e2094-BM02-S\u003c\/strong\u003e Axis Module) provides direct physical power conversion and servo loop execution. The unit functions as a single-wide inverter module designed to manage 400\/460V AC input voltage while delivering a continuous power output of 6.6 kW and a peak current output of 15 A to the connected servo axis.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2094-BM02-S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e400\/460 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Power Output\u003c\/td\u003e\n\u003ctd\u003e6.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003eSingle-Wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on drive load and duty cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Motion Networking \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 2094-BM02-S integrates directly into the Kinetix 6000 system backplane, utilizing the internal bus for high-speed communication between the axis module and the control interface. To ensure stable performance across the drive system, firmware flash compatibility must be verified with the existing motion controller during integration. The module supports deterministic EtherNet\/IP or SERCOS communication topologies, depending on the system configuration. Proper synchronization of the backplane bus communication velocity is necessary to maintain precise motor positioning and to prevent timing jitter within the motion loop.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 2094-BM02-S be hot-swapped while the Kinetix 6000 system is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. The drive system must be de-energized, and the DC bus must be fully discharged before attempting to remove or install any axis module to prevent electrical damage to the backplane connectors.\u003c\/p\u003e\n\u003cp\u003eQ: What is the significance of the \"S\" suffix in this model?\u003c\/p\u003e\n\u003cp\u003eA: The \"S\" suffix indicates that this specific module is equipped with integrated safe-off capability, allowing the drive to perform a safe stop function without disconnecting the AC input to the drive bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Stability\u003c\/strong\u003e: Ensure the Kinetix 6000 chassis is mounted on a flat, grounded, vertical surface. The module must be seated firmly into the interface module backplane to ensure reliable communication and power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Maintain a minimum clearance of 50 mm above and below the module to facilitate proper air circulation and thermal heat sink dissipation. Ensure the ambient cabinet temperature does not exceed 50 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Use shielded motor cables to mitigate electromagnetic interference (EMI). Connect the cable shield to the designated ground lug on the chassis to ensure effective common-mode noise suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Specifications\u003c\/strong\u003e: Use a calibrated torque wrench for terminal connections. Follow the recommended torque values provided in the installation manual to prevent mechanical failure of the terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53559494017208,"sku":"2094-BM02-S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2094-BM02-S.jpg?v=1780891010","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-2094-bm02-s-kinetix-6000-axis-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}