{"product_id":"allen-bradley-2711p-b15c22d9p-panelview-plus-7-performance-operator-terminal","title":"Allen-Bradley 2711P-B15C22D9P PanelView Plus 7 Performance Operator Terminal","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2711P-B15C22D9P\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2711P-B15C22D9P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperator Terminal, operates as a dedicated hardware component for human-machine interface visualization and control interaction within industrial Ethernet networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2711P-B15C22D9P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\/Global\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.63 kg (8.00 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e304 x 228 mm (Display Area)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified (Standard industrial range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 W (2.1 A at 24 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 inch Color TFT, 1024 x 768 XGA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512 MB RAM, 512 MB nonvolatile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Ethernet, 3 x USB host\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-B15C22D9P integrates into Ethernet-based control platforms utilizing dual Ethernet ports to support Device Level Ring (DLR) topologies, providing network resiliency. Deterministic communication is managed via the EtherNet\/IP protocol, requiring precise IP configuration to maintain data throughput. The terminal firmware supports robust I\/O density scaling through application object linking, allowing for the consolidation of data from multiple controllers. Firmware flash compatibility is controlled via the internal operating system, and users must ensure that deployed application runtime versions align with the terminal bootloader requirements to prevent communication latency or visualization failures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the LED backlight be replaced if it reaches the 50,000-hour limit?\u003c\/p\u003e\n\u003cp\u003eA: No. The white LED backlight assembly is integrated into the display module and is not field-replaceable. Once the display reaches half-brightness, the entire operator terminal unit must be decommissioned or replaced.\u003c\/p\u003e\n\u003cp\u003eQ: Are there restrictions on the USB host ports?\u003c\/p\u003e\n\u003cp\u003eA: The three USB host ports are intended for external storage, peripheral input devices (such as keyboards or mice), or firmware update media. They do not support direct PLC communication and should not be used to power high-draw external devices that exceed the port current rating.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe terminal must be installed in an enclosure cutout with a minimum clearance as specified in the installation manual to ensure adequate airflow. Ensure the bezel gasket is free of debris to maintain the integrity of the NEMA\/IP seal against the panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect to a 24 V DC source (range 18-30 V DC). Use a dedicated power supply that is isolated from inductive loads to minimize electromagnetic noise injection into the terminal logic circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA chassis ground lug is provided on the rear of the unit. This must be bonded to the enclosure ground bus using a low-impedance conductor to mitigate transient surges and ensure signal stability on the Ethernet ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Interaction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe analog resistive touchscreen is rated for 1 million actuations. Avoid using sharp tools or excessive force (above 100 g) during operation, as this will lead to premature wear of the resistive overlay and potential failure of the touch input logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53511115899064,"sku":"2711P-B15C22D9P","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2711P-B15C22D9P.jpg?v=1779766133","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-2711p-b15c22d9p-panelview-plus-7-performance-operator-terminal","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}