{"product_id":"allen-bradley-2711p-t12c6b2-panelview-plus-1250-panelview-terminal","title":"Allen-Bradley 2711P-T12C6B2 PanelView Plus 1250 Panelview Terminal","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711P-T12C6B2\u003c\/strong\u003e is a \u003cstrong\u003ePanelView Plus 1250 touchscreen operator terminal\u003c\/strong\u003e featuring a \u003cstrong\u003e12.1-inch color TFT display\u003c\/strong\u003e with \u003cstrong\u003e800 × 600 SVGA resolution\u003c\/strong\u003e. It provides \u003cstrong\u003eEtherNet\/IP and RS-232 communication\u003c\/strong\u003e, DC power input, and runs \u003cstrong\u003eWindows CE 6.0\u003c\/strong\u003e for advanced HMI applications in industrial automation environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e PanelView Plus 1250\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Size:\u003c\/strong\u003e 12.1 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Type:\u003c\/strong\u003e Color active-matrix TFT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 800 × 600 pixels (SVGA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Touchscreen (analog resistive)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e EtherNet\/IP, RS-232\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 18–32V DC (24V DC nominal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating System:\u003c\/strong\u003e Windows CE 6.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 512 MB RAM \/ 512 MB nonvolatile memory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree User Memory:\u003c\/strong\u003e Approx. 79 MB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Ports:\u003c\/strong\u003e 2 USB host ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSD Card Slot:\u003c\/strong\u003e Hot-swappable, supports 1784-SDx and 1784-SDHCx\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Area:\u003c\/strong\u003e 246 × 184 mm (9.7 × 7.2 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCutout Dimensions:\u003c\/strong\u003e 302 × 228 mm (11.9 × 9.0 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Dimensions:\u003c\/strong\u003e 338 × 264 × 55 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e NEMA 12, 13, 4X; IP54, IP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0–55 °C (32–131 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 2.8 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge 12.1\" Color Display:\u003c\/strong\u003e SVGA resolution provides clear, detailed process visualization for complex HMI applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet\/IP Connectivity:\u003c\/strong\u003e High-speed industrial Ethernet for seamless integration with ControlLogix and CompactLogix systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual USB Host Ports:\u003c\/strong\u003e Connect keyboards, mice, printers, and USB flash drives for enhanced usability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable SD Card:\u003c\/strong\u003e Easy file transfer, firmware updates, and data logging without system shutdown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWindows CE 6.0 OS:\u003c\/strong\u003e Supports FactoryTalk View ME runtime and optional extended features including web browser and Office viewers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Enclosure:\u003c\/strong\u003e NEMA 4X\/IP65 front panel rating for washdown and harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess control visualization\u003c\/li\u003e\n\u003cli\u003eMachine operator interfaces\u003c\/li\u003e\n\u003cli\u003eProduction line monitoring\u003c\/li\u003e\n\u003cli\u003eBatch control systems\u003c\/li\u003e\n\u003cli\u003eWater\/wastewater SCADA\u003c\/li\u003e\n\u003cli\u003ePackaging and material handling HMI\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout:\u003c\/strong\u003e Prepare panel cutout of \u003cstrong\u003e302 × 228 mm (11.9 × 9.0 in)\u003c\/strong\u003e per the installation template.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the terminal to the panel using the provided mounting clips. Torque to specification for NEMA 4X seal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect 24V DC (18–32V DC range) to the power terminals. Use appropriate wire gauge for the current draw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connection:\u003c\/strong\u003e Connect EtherNet\/IP cable to the RJ45 port for controller communication and remote access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232 Setup:\u003c\/strong\u003e Use the RS-232 port for printer connection or legacy serial device integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB\/SD Configuration:\u003c\/strong\u003e Insert SD card or USB drive for application backup, firmware update, or data logging setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Loading:\u003c\/strong\u003e Develop HMI application using FactoryTalk View Machine Edition and download via Ethernet or removable media.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What software is required to develop applications for the 2711P-T12C6B2?\u003c\/strong\u003e\u003cbr\u003e\nA: FactoryTalk View Machine Edition (version 6.0 or later) is required for HMI application development.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use VNC to remotely access this terminal?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. With FactoryTalk ViewPoint software (version 1.2 or later), remote users can access terminal displays via standard web browsers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the backlight replaceable?\u003c\/strong\u003e\u003cbr\u003e\nA: The CCFL backlight is field-replaceable with a minimum 50,000-hour life at 25 °C.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between standard and extended features Windows CE 6.0?\u003c\/strong\u003e\u003cbr\u003e\nA: Extended features include Internet Explorer, remote desktop connection, media player, and Microsoft Office file viewers.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify panel cutout dimensions (302 × 228 mm) before ordering\u003c\/li\u003e\n\u003cli\u003eConfirm 24V DC power availability at the installation location\u003c\/li\u003e\n\u003cli\u003eEnsure EtherNet\/IP network infrastructure is in place for controller communication\u003c\/li\u003e\n\u003cli\u003eOrder FactoryTalk View Machine Edition software if not already available\u003c\/li\u003e\n\u003cli\u003eConsider SD card (1784-SDx) for application backup and data logging\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53803496439992,"sku":"2711P-T12C6B2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2711P-T12C4D11r180.png?v=1784796204","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-2711p-t12c6b2-panelview-plus-1250-panelview-terminal","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}