{"product_id":"allen-bradley-440r-em4r2d-guardmaster-safety-relay","title":"Allen-Bradley 440R-EM4R2D Guardmaster Safety Relay","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 440R-EM4R2D\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e440R-EM4R2D\u003c\/strong\u003e Safety Relay, operates as a dedicated hardware component for safety-rated circuit expansion and time-delayed stop execution within industrial control systems. This module provides direct physical\/electrical execution of safety functions, utilizing one single-wire safety input to trigger four normally open (N\/O) safety relay outputs and one solid-state auxiliary output upon the expiration of a pre-configured time delay.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e440R-EM4R2D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mount form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard (ambient dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e1 Single-wire safety input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4 N\/O safety relay, 1 solid-state auxiliary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIS Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe 440R-EM4R2D is designed to maintain system integrity through fail-safe state execution in safety-critical circuits. When the single-wire safety input is de-energized, the internal relay logic initiates the configured time delay before opening the safety outputs. The module provides galvanic isolation between the input control circuit and the output switching circuit, minimizing the risk of fault propagation. The solid-state auxiliary output operates as a non-safety feedback channel, providing real-time status monitoring of the relay state to the primary safety controller.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the time delay be adjusted while the module is energized?\u003c\/p\u003e\n\u003cp\u003eA: Adjustment of the time delay must be performed according to the configuration settings defined in the product manual. Verify that the time delay period is appropriate for the machine’s coast-down characteristics to ensure compliant operation.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with other Guardmaster safety relays?\u003c\/p\u003e\n\u003cp\u003eA: The 440R-EM4R2D is intended for use as an expansion module. Ensure that the master safety relay is compatible with the single-wire safety input protocol utilized by this expansion unit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting:\u003c\/strong\u003e Ensure the module is securely latched onto a 35 mm DIN-rail. Proper mounting ensures vibration resistance and reliable electrical contact through the chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements:\u003c\/strong\u003e Use appropriate wire gauges for the 24 VDC supply and relay outputs. Ensure all wiring is routed to minimize electromagnetic interference, particularly for the safety input line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the 24 VDC common to a clean earth ground to establish a stable reference potential for the control circuit. This is necessary for the consistent operation of the internal safety logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Protection:\u003c\/strong\u003e Install external fuses on the relay outputs to protect the contacts from overcurrent and short-circuit conditions, as internal relay contacts can weld if subjected to current levels exceeding their rated capacity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53546622353592,"sku":"440R-EM4R2D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/440R-EM4R2D.jpg?v=1780567367","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-440r-em4r2d-guardmaster-safety-relay","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}