{"product_id":"allen-bradley-80026-619-01-r-pressure-transducer","title":"Allen-Bradley 80026-619-01-R Pressure Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e80026-619-01-R\u003c\/strong\u003e is a \u003cstrong\u003epressure sensor transducer\u003c\/strong\u003e manufactured by \u003cstrong\u003eAllen-Bradley (Rockwell Automation)\u003c\/strong\u003e. It converts process pressure into a standard \u003cstrong\u003e4–20 mA or 0–10 VDC output signal\u003c\/strong\u003e for integration with PLC, DCS, and SCADA systems. With a \u003cstrong\u003estainless steel housing\u003c\/strong\u003e and wide pressure range, this transducer delivers reliable measurement in hydraulic, HVAC, water treatment, and general industrial automation applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Range:\u003c\/strong\u003e 0–100 psi to 0–5000 psi (configurable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e 4–20 mA or 0–10 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Stainless steel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Threaded or flange options\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.20 lbs (1.0 kg)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.25% of full scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide Pressure Span:\u003c\/strong\u003e Configurable from 0–100 psi to 0–5000 psi covers everything from light pneumatic systems to heavy hydraulic presses.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Output Options:\u003c\/strong\u003e Select 4–20 mA for long cable runs or 0–10 V for high-impedance input cards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Housing:\u003c\/strong\u003e 316 stainless steel construction withstands aggressive media and outdoor exposure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e24 VDC Loop Power:\u003c\/strong\u003e Standard industrial supply voltage eliminates specialized power supplies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiple Process Connections:\u003c\/strong\u003e Threaded NPT and flange options adapt to global piping standards.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the accuracy class of the 80026-619-01-R?\u003c\/strong\u003e\u003cbr\u003eA: The transducer delivers \u003cstrong\u003e±0.25% of full-scale accuracy\u003c\/strong\u003e across the calibrated pressure range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the output signal be configured in the field?\u003c\/strong\u003e\u003cbr\u003eA: Output selection (4–20 mA vs. 0–10 V) is typically factory-configured. Verify your part number suffix or consult the datasheet for field-configurable variants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this transducer suitable for outdoor installation?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e-40°C to +85°C\u003c\/strong\u003e temperature range and stainless steel housing support outdoor use. Add a weatherhead or enclosure for additional moisture protection.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the transducer on a \u003cstrong\u003eprocess tap or manifold\u003c\/strong\u003e using Teflon tape or appropriate thread sealant.\u003c\/li\u003e\n  \u003cli\u003eConnect \u003cstrong\u003e24 VDC power\u003c\/strong\u003e to the supply terminals and the signal wire to the PLC analog input card.\u003c\/li\u003e\n  \u003cli\u003eFor 4–20 mA loops, verify loop resistance does not exceed the transducer's maximum load rating.\u003c\/li\u003e\n  \u003cli\u003eApply a \u003cstrong\u003eknown pressure reference\u003c\/strong\u003e (calibrator or deadweight tester) and verify output at 0%, 50%, and 100% span.\u003c\/li\u003e\n  \u003cli\u003eZero and span trim if adjustable trim pots are provided on the transducer body.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Range:\u003c\/strong\u003e Select a range where normal operating pressure sits at 50–75% of full scale for optimal resolution and overpressure protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Compatibility:\u003c\/strong\u003e Match 4–20 mA to PLC analog input cards with 250 Ohm burden resistors, or 0–10 V to high-impedance voltage inputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMedia Compatibility:\u003c\/strong\u003e Verify wetted materials (stainless steel diaphragm, O-rings) are compatible with your process fluid.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e For pulsating flows or rapid pressure cycling, specify a transducer with dampening or snubber accessories.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":53993615491256,"sku":"80026-619-01-R","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/80026-088-01_2r270_a5501bdc-f368-4ee5-b594-2064ad607092.png?v=1787732743","url":"https:\/\/www.globalpetroparts.com\/products\/allen-bradley-80026-619-01-r-pressure-transducer","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}