{"product_id":"analog-i-o-modules-140ari03010-schneider-electric","title":"Analog I\/O Modules 140ARI03010 Schneider Electric","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e140ARI03010 (Part Number: 140ARI03010)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision 8-channel analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Quantum\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform, designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTD temperature sensors\u003c\/strong\u003e. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePlatinum (Pt)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNickel (Ni)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprobes, providing accurate and reliable temperature monitoring for industrial processes.\u003c\/p\u003e\n\u003cp\u003eThe module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e13-bit resolution\u003c\/strong\u003e, robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echannel-to-bus isolation\u003c\/strong\u003e, and a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efull LED diagnostic array\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor channel and wiring fault detection, all in the standard Quantum rack form factor.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Differential (RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported RTD Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePt 100\/200\/500\/1000, Ni 100\/200\/500\/1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePt: -10 to 450 °C (standard), -200 to 850 °C (extended)\u003cbr\u003eNi: -60 to 180 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C absolute, ±0.01 % linearity, ±0.5 °C at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e640 ms (2- or 4-wire), 1200 ms (3-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel-to-bus: 1780 V AC \/ 2500 V DC\u003cbr\u003eChannel-to-channel: 300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Green LED (Bus Active), 1 Red LED (External Fault)\u003cbr\u003e8 Green LEDs (Channel Status), 8 Red LEDs (Channel Fault\/Broken Wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA (1 W dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC and thermal management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density RTD feedback integration without external transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eNotes\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroken wire detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincluded; corresponding channel LED illuminates on fault\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMixed 2-wire and 3-wire RTDs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupported, but update rate follows slowest channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermocouples not supported\u003c\/strong\u003e; use 140ATI series for thermocouple inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52505721405624,"sku":"140ARI03010","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140ARI030102.jpg?v=1769496348","url":"https:\/\/www.globalpetroparts.com\/products\/analog-i-o-modules-140ari03010-schneider-electric","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}