{"product_id":"analog-input-module-900a01-0001-honeywell","title":"Analog Input Module 900A01-0001 Honeywell","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e900A01-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density universal analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell HC900 Control System\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeight independent channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapable of interfacing with a wide range of sensor types—including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouples, RTDs, and standard voltage\/current transmitters\u003c\/strong\u003e—without the need for external signal conditioning.\u003c\/p\u003e\n\u003cp\u003eThis module performs\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal linearization, cold-junction compensation, and galvanic isolation\u003c\/strong\u003e, ensuring precise digital acquisition for critical process applications. Its flexibility makes it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal processing, pharmaceutical manufacturing, water treatment, and HVAC control\u003c\/strong\u003e, where multiple sensor types coexist within a single I\/O rack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900A01-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell HC900 Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Universal Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25–40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHC900 I\/O Rack (DIN rail compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring high-temperature furnaces with multiple thermocouple types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasuring temperature and humidity via RTDs and voltage sensors in cleanrooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Dosing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracking 4–20 mA flow and level signals for precise reagent control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-point temperature sensing for industrial chilling and heating units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate terminal block?\u003c\/strong\u003e\u003cbr\u003eYes. The 900A01-0001 requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20-terminal Remote Termination Panel (RTP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEuro-style terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., part number 900TE1-0001) for field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan different input types be mixed on the same module?\u003c\/strong\u003e\u003cbr\u003eAbsolutely. Each channel is independently configurable through\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHC900 Designer software\u003c\/strong\u003e, allowing, for example, a thermocouple on Channel 1 and a 4–20 mA transmitter on Channel 2.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52521132196024,"sku":"900A01-0001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900A01-00012_2_23fe6cc2-7532-453c-bd1d-63420d0f014d.jpg?v=1770017080","url":"https:\/\/www.globalpetroparts.com\/products\/analog-input-module-900a01-0001-honeywell","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}