{"product_id":"analog-input-module-honeywell-experion-pks-8c-paih54-51307070-275","title":"Analog Input Module Honeywell Experion PKS 8C-PAIH54 51307070-275","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAIH54 (P\/N: 51307070-275)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile, high-density\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input acquisition module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Experion PKS Series 8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 single-ended input channels\u003c\/strong\u003e, converting raw field signals into high-resolution digital data for use within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 control environment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike fixed-signal analog input modules, the 8C-PAIH54 supports a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewide variety of signal types\u003c\/strong\u003e, including current, voltage, and direct temperature sensor inputs. Its rugged industrial design ensures stable and accurate signal processing even in extreme operating conditions, maintaining data integrity from the field level to the control room.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngineering P\/N\u003c\/td\u003e\n\u003ctd\u003e51307070-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16, Single-Ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signals\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, 0–10 VDC, RTD, Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion\u003c\/td\u003e\n\u003ctd\u003eHigh-speed A\/D with noise filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSeries 8 Chassis \/ Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe 8C-PAIH54 is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erefining, chemical, and pharmaceutical facilities\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere multiple sensor technologies coexist, such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePressure and flow transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRTDs and thermocouples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy supporting mixed signal types on a single module, it\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereduces hardware variety\u003c\/strong\u003e, simplifies engineering, and optimizes control cabinet space.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 8C-PAIH54 require external signal conditioning for thermocouples?\u003c\/strong\u003e\u003cbr\u003eA: No. The module directly accepts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple and RTD inputs\u003c\/strong\u003e, performing internal linearization and cold-junction compensation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 8C-PAIH54 compatible with C200 controllers?\u003c\/strong\u003e\u003cbr\u003eA: No. This module is designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries 8 platform\u003c\/strong\u003e, typically paired with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controllers\u003c\/strong\u003e. C200 systems require a different I\/O family, such as Chassis I\/O.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52511086215352,"sku":"8C-PAIH54 51307070-275","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/8C-PAIH54_51307070-2752.jpg?v=1769670775","url":"https:\/\/www.globalpetroparts.com\/products\/analog-input-module-honeywell-experion-pks-8c-paih54-51307070-275","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}