{"product_id":"analog-input-module-schneider-modicon-quantum-bmxart0814","title":"Analog Input Module Schneider Modicon Quantum BMXART0814","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBMXART0814\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a high-precision, isolated analog input module within the Schneider Electric Modicon X80 ecosystem (M340 and M580). This module specializes in low-level signal acquisition, supporting 8 channels of thermocouples, Resistance Temperature Detectors (RTD), and millivolt-range voltage inputs. It provides the essential interface for temperature-critical processes in chemical, power, and manufacturing sectors. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure laboratory-grade measurement accuracy in your industrial environment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermocouple (B, E, J, K, L, N, R, S, T, U), RTD (Pt100, Pt1000, Ni100, Ni1000, Cu10), Voltage, Resistor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e40 mV, \u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e80 mV, \u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e160 mV, \u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e320 mV, \u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e640 mV, \u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e1.28 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eADC Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit Sigma-Delta (15 bits + sign)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 dB at 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSampling Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 ms (Thermocouple) \/ 400 ms (Temperature Probe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated between channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1°C for most probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMTBF Reliability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e900,000 Hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40-way (2 connectors)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Signal Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 120 dB common-mode rejection and 60 dB differential-mode rejection filters out significant electrical noise. This ensures stable temperature readings even when cables run near high-power motor leads or in electrically \"noisy\" factory environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Sensor Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe BMXART0814 accepts a vast array of sensors, including 2, 3, and 4-wire RTDs and 10 different thermocouple types. This versatility reduces the need to stock multiple specialized modules, simplifying your spare parts inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Calibration Intelligence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module performs automatic internal recalibration. This feature maintains 15-bit resolution and compensates for component aging, ensuring long-term measurement stability without manual technician intervention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Fault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module monitors for open-circuit conditions across all probe types. If a sensor fails or a wire breaks, the channel-specific diagnostic LED turns red, allowing maintenance teams to identify the exact point of failure instantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle Cold Junction Compensation (CJC) for thermocouples?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BMXART0814 performs external Cold Junction Compensation via a Pt100 probe. This method provides superior accuracy compared to internal sensors by measuring the actual terminal temperature where the thermocouple wires connect.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different sensor types on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can configure each of the 8 channels independently within the programming software (EcoStruxure Control Expert), allowing you to mix RTDs and thermocouples on a single module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require external power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws its primary operating power from the X80 backplane (150 mA at 3.3V DC and 50 mA at 24V DC). You must ensure your rack power supply can accommodate these requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if an input exceeds the nominal voltage range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features a permitted overload protection of\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e7.5 V. This protection prevents hardware damage from transient overvoltage, though measurements outside the configured range will trigger an I\/O error status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53413628575928,"sku":"BMXART0814","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/BMXART0814_2.jpg?v=1777348614","url":"https:\/\/www.globalpetroparts.com\/products\/analog-input-module-schneider-modicon-quantum-bmxart0814","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}