{"product_id":"analog-input-modules-ge-versamax-ic200alg432","title":"Analog Input Modules GE VersaMax IC200ALG432","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200ALG432\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC200ALG432\u003c\/strong\u003e Analog Output Module utilized to execute physical loop drive current generation and analog signal replication tasks across VersaMax Distributed I\/O platforms. The module interfaces directly with downstream analog positioners, variable speed drive references, and physical control valve actuators, converting digital software registers into electrical analog currents or voltages via internal digital-to-analog conversion circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG432\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC, -10 to +10 VDC, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e13-bit bipolar, 12-bit unipolar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e50 mA maximum at 5 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (19.2 to 30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA maximum at 24 VDC (plus loop current loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eNone (channels share a common return reference)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-to-Logic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC continuous dielectric boundary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 67 mm x 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 8-channel hardware sub-assembly docks directly into native backplane carriers without decreasing or altering the standard backplane bus communication velocity across adjacent discrete or analog cards. This high-density channel layout allows structured local I\/O density scaling inside control enclosures, relaying output digital registers directly from memory tables assigned by network adapter interfaces scanning over Profinet \/ EtherNet\/IP deterministic networks. Module parameter setups and calibration profiles match standard data variables maintained by internal firmware flash compatibility blocks mapped at the head-end sub-rack station.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the physical grounding and terminal layout of the IC200ALG432 permit active hot-swap extraction limits?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware design allows hot-swap module extraction and insertion cycles while the remainder of the rack carrier stays powered up, provided that the external 24 VDC auxiliary load and loop circuits are isolated from the terminal block beforehand to prevent transient capacitive arcing.\u003c\/p\u003e\n\u003cp\u003eQ: How does the output circuit array respond if the external 24 VDC auxiliary loop supply falls out of range?\u003c\/p\u003e\n\u003cp\u003eA: When internal voltage validation loops confirm that the incoming auxiliary power has dropped below 19.2 VDC, the module halts internal data update sweeps, sends a diagnostic loop fault message to the master CPU, and clamps all 8 analog channels to a zero-drive state (0 mA or 0 VDC).\u003c\/p\u003e\n\u003cp\u003eQ: What actions prevent data corruption from common-mode electrical noise across adjacent output paths?\u003c\/p\u003e\n\u003cp\u003eA: Because the 8 channels are single-ended and share a common electrical return line, all field actuators connected to the module must be isolated from ground at the field side to block the formation of internal ground loop currents.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Carrier Placement\u003c\/strong\u003e: Align the module housing rear tracks with the target slot on the passive VersaMax carrier bracket. Apply steady vertical force downward until both side plastic latch clips lock flush onto the frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Wire Metric Constraints\u003c\/strong\u003e: Strip the outer insulation of all twisted shielded instrumentation pairs back by exactly 6 mm before sliding the bare wire ends into the clamp terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Screw Fastening Torque\u003c\/strong\u003e: Secure all field wire termination screws using a manual calibration tool adjusted to a precise mechanical limit of 0.5 Nm to prevent high contact resistance under industrial thermal cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Alignment\u003c\/strong\u003e: Terminate the analog signal cable shield drain wires directly to the designated enclosure grounding bar on the carrier rail frame. Keep the opposite side of the shield ungrounded at the actuator housing to eliminate loop noise paths.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53582094074040,"sku":"IC200ALG432","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC200ALG432_2.jpg?v=1781158657","url":"https:\/\/www.globalpetroparts.com\/products\/analog-input-modules-ge-versamax-ic200alg432","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}