{"product_id":"ao810-3bse008522r1-s800-i-o-analog-output-module-abb","title":"AO810 3BSE008522R1 | S800 I\/O Analog Output Module | ABB","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB AO810 (3BSE008522R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical interface for driving field devices within the S800 I\/O distributed system. This module provides eight independent analog output channels, typically used to control actuators, variable speed drives, and valve positioners. By converting digital control signals into precise analog currents, the AO810 ensures accurate process modulation in complex automation architectures. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your facility maintains peak operational integrity with factory-certified hardware.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe AO810 utilizes high-speed circuitry to deliver stable output signals:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Current (Typically 4-20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE008522R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e119 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Depth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.184 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGroupwise isolated from ModuleBus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 850 Ω (at 20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Cabinet Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim 45mm profile allows engineers to pack more I\/O points into standard control cabinets. This compact footprint solves the challenge of limited space in offshore platforms or retrofitted brownfield sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Signal Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module updates output values with minimal latency, allowing for high-performance PID control loops. This speed ensures that final control elements like steam valves react instantly to process deviations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Short-Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AO810 includes internal current-limiting features. If a field cable shorts, the module protects the internal backplane and adjacent I\/O units, preventing a single wiring fault from causing a total system shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Heat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEfficient power management within the module minimizes heat buildup. This reduces the thermal load on the cabinet cooling system and extends the MTBF (Mean Time Between Failures) of the entire S800 station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Hot-Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen paired with the correct Module Termination Unit (MTU), the AO810 supports hot-replacement. Maintenance teams replace faulty modules without powering down the station, maintaining process continuity and reducing downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of field devices does the AO810 typically control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngineers primarily use the AO810 to drive 4-20 mA devices such as I\/P converters, control valve positioners, and frequency converters (VFDs) for motor speed control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the AO810 requires a 24 V DC external power supply to drive the output current loops. The module pulls logic power from the ModuleBus, but field-side current originates from the external supply to ensure signal strength over long cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum load the AO810 can drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports a maximum load impedance of 850 Ω at 20 mA. This high drive capability allows for long cable distances between the I\/O cabinet and the field device without signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot a channel failure on the AO810?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the front-mounted LEDs. A \"Fault\" (F) LED indicates internal module errors, while the \"Warning\" (W) LED often points to external supply issues. Use the ABB controller software to view detailed diagnostic buffers for specific channel errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53172600996024,"sku":"AO810 3BSE008522R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/AO8103BSE008522R11.jpg?v=1774838907","url":"https:\/\/www.globalpetroparts.com\/products\/ao810-3bse008522r1-s800-i-o-analog-output-module-abb","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}