{"product_id":"ao895-3bsc690087r1-abb-s800-i-o-intrinsic-safety-analog-output-module","title":"AO895 3BSC690087R1 | ABB S800 I\/O Intrinsic Safety Analog Output Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB AO895 (3BSC690087R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a high-precision control interface for field devices located in hazardous industrial environments. This 8-channel module integrates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntrinsic Safety (IS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebarriers, allowing direct connection to 4...20 mA actuators and valve positioners in explosive atmospheres without external isolators. Furthermore, the AO895 features full\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransparency, enabling bi-directional digital data exchange between the DCS and smart field instruments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring compliance with strict safety regulations and maximizing plant uptime.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe AO895 delivers laboratory-grade signal accuracy with robust output capabilities:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels (Unipolar Single-ended)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4...20 mA (Under\/Over range: 2.5 \/ 22.4 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHART Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (Includes dedicated Tx LED for activity)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntrinsic Safety\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (S800 Mechanics)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;725 Ω at 20 mA; \u0026lt;625 Ω at 22 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTyp. 0.05%, Max. 0.1% at 650 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 ms (10% to 90%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.25 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGroupwise isolated from ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF(ault), R(un), W(arning), O(SP), Tx (HART)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Direct-Drive:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe built-in Intrinsic Safety barriers allow the AO895 to drive actuators in Zone 0, 1, or 2 without secondary hardware. This consolidation reduces cabinet footprint, simplifies wiring documentation, and eliminates the voltage drop typically associated with external Zener barriers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Asset Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module passes HART digital signals through the analog loop. This allows maintenance teams to perform remote calibration, valve signature analysis, and device configuration directly from the control room, significantly reducing field-site exposure and labor costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShort-Circuit Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe output stage features short-circuit proof current limiting. If a field cable sustains damage or a short occurs, the module protects the internal backplane logic and limits the current to safe levels, preventing cascading hardware failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Thermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a typical temperature drift of only 50 ppm\/°C, the AO895 maintains precise control setpoints across wide temperature fluctuations. This stability ensures consistent valve positioning in non-climate-controlled remote I\/O shelters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProactive Fault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supervises the internal process supply and monitors for open-wire conditions (when set above 1 mA). The front-panel LEDs provide immediate visual feedback, while the DCS receives detailed status words to pinpoint exact channel failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the AO895 support Output Set as Preset (OSP) mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module includes an \"O\" LED on the front panel to indicate OSP status. This feature allows the outputs to drive to a predetermined \"safe\" value if communication with the controller fails, ensuring the process enters a controlled state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable resistance the AO895 can handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAt a standard 20 mA output, the module drives a total load of up to 725 Ω. This accommodates long field cable runs and high-impedance valve positioners without losing signal integrity or resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the HART Tx LED assist in troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Tx LED flashes during active digital communication. If the DCS fails to retrieve device data but the Tx LED is inactive, the issue likely resides in the software configuration or the module; if it flashes but no data returns, the fault typically lies with the field device or cable interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs external 24V DC power required for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module draws logic power from the Modulebus (approx. 130 mA), it requires an external +24 V DC supply (typ. 250 mA) to drive the 4-20 mA current loops through the Intrinsic Safety barriers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53172603551928,"sku":"AO895 3BSC690087R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/AO8953BSC690087R1.jpg?v=1774839222","url":"https:\/\/www.globalpetroparts.com\/products\/ao895-3bsc690087r1-abb-s800-i-o-intrinsic-safety-analog-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}