{"product_id":"baseplates-and-racks-series-90-70-ic697chs750-ge-fanuc","title":"Baseplates and Racks Series 90-70 IC697CHS750 GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697CHS750\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC697CHS750\u003c\/strong\u003e Central Processing Unit Rack utilized to execute structural chassis optimization and electrical interconnection across Series 90-70 platforms. The physical base unit establishes the necessary backplane trace segments to distribute localized logic voltages and synchronize parallel word-addressing architectures between processing units and hardware modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697CHS750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.27 kg (5.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e483 x 133 x 178 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane current load capacity up to 20 A maximum at +5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003e5 functional slots (1 dedicated slot for power supply module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Configuration\u003c\/td\u003e\n\u003ctd\u003eRear panel mount or standard 19-inch rack enclosure layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Bus Type\u003c\/td\u003e\n\u003ctd\u003eVME standard parallel bus structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Frame Material\u003c\/td\u003e\n\u003ctd\u003eZinc-plated heavy steel alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 VAC continuous from backplane bus lines to metal frame chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe baseline hardware motherboard provides structural support to maintain deterministic backplane bus communication velocity parameters across active slot designations. Address configurations and system expansion rules are governed by underlying copper track traces that manage local multi-slot scaling without code-level degradation. The physical chassis parameters ensure seamless firmware flash compatibility layers across processing assets while supporting direct module interlinks linked to remote Profinet or EtherNet\/IP deterministic networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can standard Series 90-30 modules be physically inserted into the IC697CHS750 baseplate slots?\u003c\/p\u003e\n\u003cp\u003eA: No. The physical dimensions and electrical pin layouts conform strictly to the larger Series 90-70 VME physical standard. Series 90-30 cards use completely different connector profiles and are structurally incompatible with this backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current capacity limit allowed for the internal +5 VDC logic plane on this specific rack?\u003c\/p\u003e\n\u003cp\u003eA: The physical design limits the cumulative parallel current distribution loop to a maximum threshold of 20 A continuous. Total current draw from the central processing unit and matching input\/output modules must remain within this boundary.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mechanical Placement\u003c\/strong\u003e: Anchor the rack structure firmly onto a flat structural subpanel or inside a 19-inch electronic cabinet enclosure. Maintain a minimum vertical gap of 75 mm above and below the chassis to allow free ambient thermal convection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding Track\u003c\/strong\u003e: Secure a heavy-gauge, green-jacketed copper grounding strap to the dedicated brass grounding bolt located on the bottom frame perimeter of the steel rack assembly. Connect this line directly to the primary enclosure star ground bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Slot Seating Procedure\u003c\/strong\u003e: Isolate upstream electrical potential sources before handling hardware. Align the top and bottom edges of the card assembly within the plastic guide tracks and push until the internal pins mate completely with the VME backplane socket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief Routing\u003c\/strong\u003e: Route external signal lines through the integrated wiring trays separate from high-current three-phase distribution conduits to prevent electromagnetic interference across the parallel bus.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53518858813624,"sku":"IC697CHS750","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC697CHS750_1.jpg?v=1779961189","url":"https:\/\/www.globalpetroparts.com\/products\/baseplates-and-racks-series-90-70-ic697chs750-ge-fanuc","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}