{"product_id":"bently-nevada-10513-02-3300-series-system-monitor","title":"Bently Nevada 10513-02 3300 Series System Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 10513-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the primary System Monitor for the 3300 Series Machinery Protection System. This module occupies the first slot of the instrument rack and performs critical supervisory roles, including rack diagnostics, alarm resetting, and power monitoring. It ensures the entire rack complies with the American Petroleum Institute’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAPI 670\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandard for machinery protection. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estock, guaranteeing that your legacy monitoring infrastructure remains operational and safe.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 3300 Series utilizes specific options for its system monitors to match industrial requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e10513-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard System Monitor (Internal Termination)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e10513-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Monitor with External Termination \/ Communication Options\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-XX\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecialized firmware or labeling options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 10513-02 coordinates data flow and status reporting across the rack backplane:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3300 Series Monitoring System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Level Supervisory Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully meets API 670 requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMonitoring Capabilities\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Health, Backplane Continuity, Alarm Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront panel LEDs and Buffered Output via Terminal Blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports both AC and DC rack power supplies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI 670 Compliant Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10513-02 enforces the strict voting and bypass logic required by global petrochemical standards. It prevents unauthorized alarm suppression, ensuring the system initiates a trip sequence only when true machinery faults occur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCentralized Alarm Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module provides a single point for \"Alarm Reset\" and \"Timed OK\" functions. It synchronizes the state of all individual vibration, position, and temperature monitors within the rack, simplifying operator interactions during startup and commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnline Diagnostic Surveillance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10513-02 continuously checks the integrity of the rack's power supply and backplane communication. It detects hardware failures instantly and triggers a \"System OK\" relay to notify the DCS or PLC if the machine protection system becomes compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpandable Building-Block Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports the modular philosophy of the 3300 system. It manages additional monitor modules as they are added to the rack, allowing engineers to scale the protection system from a single shaft monitor to a full-train surveillance suite without replacing the core supervisor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity Signal Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecialized circuitry within the 10513-02 filters out electrical noise from the power source. This ensures that transient spikes do not cause \"false trips\" or interfere with the sensitive eddy current signals processed by adjacent vibration monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 10513-02 compatible with all 3300 Instrument Racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 10513-02 fits into any standard 3300 series rack. However, ensure your rear termination panel matches the 10513-02 configuration, especially if you utilize external communication ports or specialized relay links.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"System OK\" LED on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"System OK\" LED indicates that both the 10513-02 and the rack power supply are functioning within tolerance. If this light turns off, the system automatically inhibits its trip relays to prevent a false shutdown while notifying the control room of a hardware fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 10513-02 monitor overspeed detection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 10513-02 supervises the rack, you must pair it with a 3300\/55 Overspeed Monitor module to perform actual speed calculations. The 10513-02 then manages the alarm state and logic for that specific speed module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does \"Brand New\" stock compare to refurbished units for 3300 systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRefurbished 3300 parts often suffer from aged capacitors and degraded logic chips. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10513-02 eliminates the risk of \"infant mortality\" and drift, ensuring your safety-critical protection system meets its full MTBF (Mean Time Between Failures) rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53450749968568,"sku":"10513-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/10513-021.jpg?v=1778317768","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-10513-02-3300-series-system-monitor","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}