{"product_id":"bently-nevada-125720-02-3500-series-4-channel-relay-output-module","title":"Bently Nevada 125720-02 3500 Series 4-Channel Relay Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 125720-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity 4-Channel Relay Output Module for the 3500 Machinery Protection System. This module provides four independent, programmable relay outputs that interface directly with Emergency Shutdown (ESD) systems or local alarm indicators. Specifically engineered for functional safety and hazardous area applications, it ensures that critical trip logic executes even in the most volatile industrial environments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eequipment, providing the verified mechanical lifespan required for SIL-rated safety loops.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eBently Nevada utilizes specific suffixes for the 125720 series to denote hardware configurations for different termination and safety requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e-01\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Relay Module\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-Hazardous \/ General Purpose\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnhanced Safety Relay Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area \u0026amp; Functional Safety Systems\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e-04\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTMR Configured Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTriple Modular Redundant (TMR) Racks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 125720-02 maintains strict electrical separation and fast response times:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125720-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-Channel Electromechanical Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada 3500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFunctional Safety (SIL) Capable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Area\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCertified for Zone 2 \/ Class I, Div 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertified Functional Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 125720-02 meets the rigorous requirements for functional safety systems. It incorporates high-reliability relay coils and contact materials that resist atmospheric corrosion, ensuring the circuit closes (or opens) instantly during a machinery over-vibration event.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExplosive Atmosphere Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecialized isolation and non-arcing design allow this module to operate safely in hazardous areas. It eliminates the need for bulky external explosion-proof enclosures for the I\/O interface, significantly reducing installation costs in refineries and chemical plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndependent Channel Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the four channels operates independently. Engineers program specific \"AND\/OR\" voting logic via the 3500 Configuration Software, allowing one module to handle multiple trip conditions (e.g., Axial Thrust and Radial Vibration) simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1.0 kg robust chassis absorbs high-frequency vibrations common on turbine decks. This mechanical damping prevents \"relay chatter,\" a phenomenon where vibration causes contacts to bounce and trigger false alarms in lighter, inferior modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGold-Plated Contact Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal relays utilize gold-plated contacts. This metallurgical choice prevents oxidation buildup during long periods of inactivity, ensuring the relay maintains low contact resistance for the moment a trip signal occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I swap a 125720-01 for a 125720-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile they share the same footprint, the -02 version carries specific certifications for hazardous areas and functional safety. You should not downgrade to a -01 in a safety-critical or hazardous environment as it may violate your plant's insurance and safety compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support \"Hot Swapping\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 3500 architecture allows you to replace the 125720-02 while the rack is powered. However, you must activate the \"Rack Bypass\" or inhibit the specific relay outputs in your DCS to prevent an accidental machinery trip during the physical replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle power failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can configure the relays as either \"Normally Energized\" or \"Normally De-energized.\" In safety systems, \"Normally Energized\" (Fail-Safe) is the standard configuration, ensuring the system initiates a trip if the 125720-02 loses power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is \"Brand New\" condition vital for relay modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRelays are mechanical components with a rated number of cycles. Used or refurbished modules often have pitted contacts or weakened coils from years of heat exposure. Only a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125720-02 guarantees the factory-rated MTBF (Mean Time Between Failures) necessary for machinery protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53450770350264,"sku":"125720-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/350060133819-01_040390e8-09fb-4e32-ac18-b34e77495c3e.jpg?v=1778319275","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-125720-02-3500-series-4-channel-relay-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}