{"product_id":"bently-nevada-176449-05-3500-64m-dynamic-pressure-monitor","title":"Bently Nevada 176449-05 3500\/64M Dynamic Pressure Monitor","description":"\u003cp\u003eConfigured for high-frequency pressure fluctuation monitoring in 3500 Series machinery protection platforms, the \u003cstrong\u003eBently Nevada 176449-05\u003c\/strong\u003e (\u003cstrong\u003e3500\/64M\u003c\/strong\u003e Dynamic Pressure Monitor) provides direct physical execution of dynamic waveform acquisition from pressure transducers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e176449-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 3500 module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.5 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input\u003c\/td\u003e\n\u003ctd\u003eDynamic Pressure Transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/64M monitor is optimized for the detection of high-speed pressure oscillations, which are indicative of fluid dynamic instabilities in turbine and compressor stages. Accurate measurement is dependent on proper eddy-current probe scaling if using associated reference sensors, or specific voltage-to-pressure scaling for dynamic pressure transducers. During commissioning, gap voltage validation (if applicable) must be verified at the -10 VDC target to maintain signal linearity. Furthermore, to preserve high-fidelity waveform data, the module employs cross-talk suppression techniques that isolate signal paths from adjacent channels, ensuring that transient events in one pressure zone are not reflected as phantom signals in others.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 3500\/64M module be configured to trigger alarms based on peak-to-peak pressure values?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The monitor allows for the configuration of alarm setpoints based on various parameters including peak-to-peak, RMS, or integrated pressure values, depending on the requirements of the monitored machinery.\u003c\/p\u003e\n\u003cp\u003eQ: Is this monitor compatible with existing 3500 rack backplanes that previously housed other M-series monitors?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 3500\/64M is designed for standard 3500 rack slot compatibility. Ensure the corresponding I\/O module is installed to provide the necessary field wiring termination for dynamic pressure signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Seating\u003c\/strong\u003e: Insert the module into the designated slot in the 3500 rack. Ensure that the backplane connector is fully engaged and the front panel retention mechanism is tightened to maintain grounding continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cabling\u003c\/strong\u003e: Use high-quality shielded twisted-pair cabling for all dynamic pressure transducer inputs. Shielding should be terminated at the I\/O module chassis ground to provide an effective low-impedance path for EMI\/RFI noise rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Use the 3500 Configuration Software to define the input range and scaling factors. Perform a functional verification test by injecting a known signal level to confirm that the monitor outputs are correctly reflected in the System 1 software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance\u003c\/strong\u003e: Regularly inspect the input terminal blocks for oxidation or loose connections, as signal instability in high-impedance pressure circuits can lead to erroneous trip logic activation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53601519796408,"sku":"3500\/64 176449-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/143488-01_83e31ecc-4c50-4e6b-8cca-5c268edaabd9.jpg?v=1781753506","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-176449-05-3500-64m-dynamic-pressure-monitor","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}