{"product_id":"bently-nevada-330101-00-50-10-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-50-10-02-00 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eConfigured for displacement measurement in rotating machinery, the \u003cstrong\u003eBently Nevada 330101-00-50-10-02-00\u003c\/strong\u003e (\u003cstrong\u003e330101-00-50-10-02-00\u003c\/strong\u003e Proximity Probe) provides direct physical signal transduction for vibration and position monitoring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e00 (0.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e50 (5.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e10 (1.0 metre)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e02 (Miniature coaxial ClickLoc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e00 (Not required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-50-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.0 in (Case Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Powered via Proximitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330101-00-50-10-02-00\u003c\/strong\u003e operates as an eddy-current transducer requiring calibration to a scaling factor of 7.87 V\/mm (200 mV\/mil). During installation, the gap voltage must be validated against the -10 VDC target midpoint to ensure linear operation within the specified measurement range. Maintaining this precise gap is necessary for accurate observation of rotor dynamics, including shaft centerline positioning and orbital vibration. Proper physical spacing between adjacent probes is mandatory for effective cross-talk suppression and signal integrity within the machine monitoring network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 1.0 metre total system length adjustable in the field?\u003c\/p\u003e\n\u003cp\u003eA: No. The \u003cstrong\u003e330101\u003c\/strong\u003e system is factory-calibrated as a matched assembly consisting of the probe, integral cable, and Proximitor sensor. Field-modifying the cable length alters the electrical impedance, which introduces non-linearity and significant measurement errors.\u003c\/p\u003e\n\u003cp\u003eQ: How is the probe case protected against corrosion?\u003c\/p\u003e\n\u003cp\u003eA: The probe body is constructed from AISI 303 or 304 stainless steel, providing high mechanical strength and corrosion resistance suitable for industrial machinery environments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the probe in a rigid, non-conductive bracket. Verify that the probe tip is perpendicular to the shaft surface to prevent measurement skew.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: The probe case is electrically conductive; verify the installation bracket is bonded to the machine housing to maintain electromagnetic immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity\u003c\/strong\u003e: Utilize the ClickLoc connector mechanism for all coupling points. Clean the mating faces with an approved electrical contact cleaner prior to assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Route coaxial cables through dedicated metallic conduit, maintaining physical separation from high-voltage AC lines to prevent induced noise on the output signal.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53598319739064,"sku":"330101-00-50-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330101-00-14-10-02-00_997402f8-2274-4398-ac0a-ec09baa67953.jpg?v=1781675254","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-330101-00-50-10-02-00-3300-xl-8-mm-proximity-probe","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}