{"product_id":"bently-nevada-330102-00-28-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330102-00-28-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eConfigured for displacement measurement in rotating machinery, the \u003cstrong\u003eBently Nevada 330103-00-28-10-02-05\u003c\/strong\u003e (\u003cstrong\u003e330102-00-28-10-02-05\u003c\/strong\u003e Proximity Probe) provides direct physical signal transduction for vibration and position monitoring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e00 (0.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e28 (2.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e10 (1.0 meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e02 (Miniature coaxial ClickLoc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e05 (CSA, ATEX, IECEx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330102-00-28-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.323 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.8 in (Case Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Powered via Proximitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330102-00-28-10-02-05\u003c\/strong\u003e utilizes an eddy-current principle for non-contact measurement, calibrated to a scaling factor of 7.87 V\/mm (200 mV\/mil). During commissioning, gap voltage validation against the -10 VDC target midpoint is mandatory to ensure linear operation. Precise gap setting is necessary for accurate analysis of rotor dynamics, including shaft orbit, radial position, and vibration magnitude. When installing multiple probes on a single bearing housing, maintain adequate separation to ensure cross-talk suppression and prevent signal interference between channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 1.0 meter total system length be modified in the field?\u003c\/p\u003e\n\u003cp\u003eA: No. The system is calibrated as a matched set (probe, extension cable, and Proximitor sensor). Field-modifying the cable length will alter the electrical impedance and introduce measurement inaccuracies.\u003c\/p\u003e\n\u003cp\u003eQ: Are these probes compatible with standard 3300 series Proximitor sensors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the system length matches the calibration of the Proximitor. Ensure the extension cable and probe are compatible with the specific Proximitor sensor firmware and revision.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the probe in a rigid, non-conductive bracket. Verify that the probe tip is perpendicular to the shaft surface to prevent measurement errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: The probe case is electrically conductive; verify the installation bracket is bonded to the machine ground to ensure electromagnetic compatibility (EMC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity\u003c\/strong\u003e: Use the ClickLoc connector mechanism and ensure mating surfaces are free of debris to prevent signal attenuation or intermittent connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Route the coaxial cable through shielded conduit, maintaining separation from high-voltage AC lines to prevent induced electromagnetic noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53598285856952,"sku":"330102-00-28-10-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330104-000-040-10-02-05_5ac627b5-af45-40e9-a9b2-4d935e506bed.jpg?v=1781668692","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-330102-00-28-10-02-05-3300-xl-8-mm-proximity-probe","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}