{"product_id":"bently-nevada-330102-00-40-10-01-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330102-00-40-10-01-05 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eConfigured for displacement measurement in rotating machinery, the \u003cstrong\u003eBently Nevada 330102-00-40-10-01-05\u003c\/strong\u003e (\u003cstrong\u003e330102-00-40-10-01-05\u003c\/strong\u003e Proximity Probe) provides direct physical signal transduction for vibration and position monitoring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e00 (No unthreaded part)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e40 (4.0 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e10 (1.0 meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e01 (ClickLoc with protector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e05 (Safety approvals included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330102-00-40-10-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 inches (Case Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Powered via Proximitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.25 mm to 2.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330102-00-40-10-01-05\u003c\/strong\u003e transducer operates on the eddy-current principle, requiring a calibrated scale factor of 7.87 V\/mm (200 mV\/mil). During installation, the gap voltage must be validated against the -10 VDC target midpoint to ensure linear operation within the displacement range. Proper gap adjustment is mandatory for accurate analysis of rotor dynamics, including shaft centerline positioning and orbital vibration. Physical spacing between adjacent probes must be maintained to provide effective cross-talk suppression and ensure signal integrity in multi-channel monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 1.0 meter total system length field-adjustable?\u003c\/p\u003e\n\u003cp\u003eA: No. The \u003cstrong\u003e330102\u003c\/strong\u003e system is factory-calibrated as a matched set including the probe, extension cable, and Proximitor sensor. Field-modifying the cable length alters the electrical impedance and will introduce significant measurement errors.\u003c\/p\u003e\n\u003cp\u003eQ: Does the Viton O-ring provide a certified high-pressure seal?\u003c\/p\u003e\n\u003cp\u003eA: The Viton O-ring is designed for differential pressure sealing at the probe tip; however, the unit is not pressure-tested as part of the standard manufacturing process. Contact the manufacturer for requirements involving high-pressure process fluid environments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the probe in a rigid, non-conductive bracket. Ensure the probe tip is perpendicular to the shaft surface to prevent measurement skew.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: The probe case is electrically conductive; verify the installation bracket is bonded to the machine housing to maintain electromagnetic compatibility (EMC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity\u003c\/strong\u003e: Use the ClickLoc connector mechanism for all coupling points. Ensure mating surfaces are clean and free of debris prior to assembly to prevent signal attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Route coaxial cables through dedicated metallic conduit, maintaining physical separation from high-voltage AC lines to prevent induced noise on the displacement signal.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53598322688184,"sku":"330102-00-40-10-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330104-00-09-10-02-00_f1ce2042-c359-4577-9a3d-70c7cab51d89.png?v=1781675811","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-330102-00-40-10-01-05-3300-xl-8-mm-proximity-probe","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}