{"product_id":"bently-nevada-330106-05-30-05-02-00-3300-xl-8-mm-proximity-probes","title":"Bently Nevada 330106-05-30-05-02-00 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330106-05-30-05-02-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330106\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contacting displacement and vibration measurement within 3500 Machinery Protection System platforms. This M10 x 1 threaded housing variant establishes an eddy-current field to monitor dynamic shaft behaviors without making physical contact with the rotating assembly.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe complete model number is constructed via specific functional options defined by the manufacturer:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330106\u003c\/strong\u003e: Base model identifier for 3300 XL 8 mm Proximity Probe with M10 x 1 metric thread.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Specifies an unthreaded length of 50 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e30\u003c\/strong\u003e: Specifies an overall case length of 300 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total Length Option designating a 0.5 metre (1.6 feet) integrated cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector Option specifying a miniature coaxial ClickLoc connector, standard cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval Option designating no hazardous area certifications required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330106-05-30-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard probe assembly weight class\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 mm case length, 50 mm unthreaded length, 0.5 m total cable length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor loop (Driven by external Proximitor Sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) scale factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Thread\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1 metric thread\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature coaxial ClickLoc connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage Validation \u0026amp; Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eMechanical deployment of this metric threaded transducer relies on physical gap voltage validation to ensure accurate data capture of rotor dynamics. During static adjustment within the mounting bracket, the probe position must be manipulated relative to the shaft target until a steady-state value of -10 VDC is obtained at the Proximitor output layer. This voltage calibration maps the physical target position to the absolute center of the linear transduction range. Maintaining this calibrated gap ensures the conversion complies with the factory eddy-current probe scaling factor of 7.87 V\/mm, while integrated cable shielding provides cross-talk suppression against adjacent sensor loops within the machine housing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 0.5-metre integrated coaxial cable be spliced or modified directly in the field?\u003c\/p\u003e\n\u003cp\u003eA: No. The integrated coaxial cable possesses specific electrical impedance constraints required for matching with the Proximitor loop circuit. Cutting or splicing the cable alters the internal capacitance and invalidates the factory 7.87 V\/mm eddy-current calibration factor.\u003c\/p\u003e\n\u003cp\u003eQ: What status behavior occurs if the ClickLoc connector is disconnected during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Disconnecting the miniature ClickLoc interface breaks the sensor loop circuit. The monitoring module detects the open circuit instantly, forces the signal output to clamp to its upper limit, and switches the associated channel status into a NOT OK fault mode to suppress false trip execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Insertion Alignment\u003c\/strong\u003e: Manually thread the M10 x 1 probe housing into the mounting bracket. Ensure no cross-threading occurs before torque is applied to the locknut assembly to prevent damage to the 300 mm stainless steel case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Bend Path Limitations\u003c\/strong\u003e: Maintain a minimum bend radius of 25.4 mm (1.0 inch) along all segments of the 0.5-meter coaxial cable. Sharp kinks or compressed routing paths degrade insulation layers and compromise shielding performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Separation Requirements\u003c\/strong\u003e: The ClickLoc connector and internal coaxial shield must remain isolated from any contact with the machine chassis or housing. Use insulated junction boxes and matching protective terminal sleeves to maintain a single-point grounding layout at the monitor rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Surface Inspection\u003c\/strong\u003e: Confirm the targeted shaft observation track matches standard calibration criteria and is free of surface scratches or structural magnetism, as these conditions cause electrical runout errors that distort vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53504079986872,"sku":"330106-05-30-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330101-00-08-05-02-00_42d95191-7f20-4921-ab84-00e281fde892.jpg?v=1779681325","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-330106-05-30-05-02-00-3300-xl-8-mm-proximity-probes","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}