{"product_id":"bently-nevada-330106-05-30-05-02-cn-3300-xl-8-mm-reverse-mount-probes","title":"Bently Nevada 330106-05-30-05-02-CN 3300 XL 8 mm Reverse Mount Probes","description":"\u003cp\u003eConfigured for non-contacting displacement and vibration measurement within 3500 Machinery Protection System platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330106-05-30-05-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330106\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReverse Mount Probe) provides direct physical\/electrical execution. This reverse mount variant utilizes high-frequency eddy-current generation to monitor dynamic shaft behaviors without making physical contact with the rotating assembly.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe complete model nomenclature breakdown for this technical configuration is defined below:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-7\"\u003e\u003c\/span\u003e\u003cstrong\u003e330106\u003c\/strong\u003e\u003cspan class=\"citation-7 citation-end-7\"\u003e: Base model number for 3300 XL 8 mm Reverse Mount Probe (3\/8-24 UNF-2A thread parameters).\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Specifies the overall probe length option of 0.5 inches (12.7 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e30\u003c\/strong\u003e: Specifies the case length option of 3.0 inches (76.2 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-6\"\u003e\u003c\/span\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003cspan class=\"citation-6 citation-end-6\"\u003e: Total Length Option designating a 0.5 metre (1.6 feet) integrated cable length.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-5\"\u003e\u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan class=\"citation-5 citation-end-5\"\u003e: Connector Option specifying a miniature coaxial ClickLoc connector.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Agency Approval Option designating country-specific regulatory compliance certificates (including NEPSI hazardous area markings).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330106-05-30-05-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard reverse mount probe weight class\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 mm (0.5 inches) overall probe length, 76.2 mm (3.0 inches) case length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive sensor loop (Driven by external Proximitor Sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF-2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTarget Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 4140 steel standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils), starting approximately 0.25 mm from probe face\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncremental Scale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) +\/-5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency Response\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 10 kHz, +0\/-3 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage Validation and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eMechanical deployment of this transducer relies on physical gap voltage validation to ensure accurate data capture of rotor dynamics. During static adjustment within the reverse mount housing, the probe position must be manipulated relative to the shaft target until a steady-state value of -10 VDC is obtained at the Proximitor output layer. This voltage calibration maps the physical target position to the absolute center of the linear transduction range, which spans 2.0 mm (80 mils). Maintaining this calibrated gap ensures the conversion complies with the factory eddy-current probe scaling factor of 7.87 V\/mm (200 mV\/mil) over a dynamic frequency response range of 0 to 10 kHz, while integrated cable shielding provides cross-talk suppression against adjacent sensor loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific installation parameter does the CN suffix impact?\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-4 citation-end-4\"\u003eA: The CN suffix dictates country-specific regulatory compliance, certifying the hardware interface under regional standards like NEPSI for hazardous environments.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eInstallation wiring must adhere strictly to local intrinsic safety entity parameters specified in the CN field notification documentation.\u003c\/p\u003e\n\u003cp\u003eQ: What status behavior occurs if the ClickLoc connector is disconnected during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Disconnecting the miniature ClickLoc interface breaks the sensor loop circuit. The monitoring module detects the open circuit instantly, forces the signal output to clamp to its upper limit, and switches the associated channel status into a NOT OK fault mode to suppress false trip execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Insertion Alignment\u003c\/strong\u003e: Manually thread the 3\/8-24 UNF-2A probe housing into the reverse mount sleeve bracket. Ensure no cross-threading occurs before torque is applied to the locknut assembly to prevent damage to the 76.2 mm case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Bend Path Limitations\u003c\/strong\u003e: Maintain a minimum bend radius of 25.4 mm (1.0 inch) along all segments of the 0.5-meter coaxial cable. Sharp kinks or compressed routing paths degrade insulation layers and compromise shielding performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Separation Requirements\u003c\/strong\u003e: The ClickLoc connector and internal coaxial shield must remain isolated from any contact with the machine chassis or housing. Use insulated junction boxes and matching protective terminal sleeves to maintain a single-point grounding layout at the monitor rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Surface Inspection\u003c\/strong\u003e: Confirm the targeted shaft observation track matches the AISI 4140 steel standard calibration criteria and is free of surface scratches or structural magnetism, as these conditions cause electrical runout errors that distort vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53504080216248,"sku":"330106-05-30-05-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330101-00-08-05-02-00_eb35a463-736b-44a2-963c-bc9d19679f20.jpg?v=1779681478","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-330106-05-30-05-02-cn-3300-xl-8-mm-reverse-mount-probes","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}