{"product_id":"bently-nevada-330173-00-06-10-02-00-3300-5-mm-proximity-transducer","title":"Bently Nevada 330173-00-06-10-02-00 3300 5 mm Proximity Transducer","description":"\u003cp\u003eConfigured for high-frequency vibration and axial position measurement in machine monitoring systems, the \u003cstrong\u003eBently Nevada 330173-00-06-10-02-00\u003c\/strong\u003e (\u003cstrong\u003e330173\u003c\/strong\u003e 5 mm Proximity Transducer) provides direct physical execution of non-contact displacement sensing. This assembly translates mechanical shaft movement into electrical signals for interpretation by the associated Proximitor sensor unit.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330173\u003c\/td\u003e\n\u003ctd\u003eBase Model Number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0.0 mm unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e60 mm overall case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 metre (3.3 feet) total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo agency approval option specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330173-00-06-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e60 mm case; 1.0 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eNon-contact vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 330173 system relies on precise eddy-current probe scaling to ensure linear displacement output, typically maintaining 7.87 V\/mm (200 mV\/mil) for AISI 4140 steel targets. During initial commissioning, technicians must perform gap voltage validation at the terminal strip of the Proximitor sensor; a reading of -10 VDC at the linear center of the probe range is the standard benchmark for accurate rotor dynamics monitoring. Proper cross-talk suppression is achieved by routing the integral coaxial cable through dedicated metallic conduit, ensuring physical isolation from AC power lines or high-frequency switching sources that could introduce noise into the transducer loop.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the ClickLoc connector be removed to facilitate installation through tight conduit?\u003c\/p\u003e\n\u003cp\u003eA: No. The ClickLoc connector is factory-molded to the coaxial cable to maintain specific electrical impedance and capacitive characteristics. Removal or field-modification will invalidate the system calibration and introduce signal measurement errors.\u003c\/p\u003e\n\u003cp\u003eQ: How is the probe sensitivity affected if the target material is not AISI 4140 steel?\u003c\/p\u003e\n\u003cp\u003eA: The probe scale factor is dependent on the magnetic permeability and electrical resistivity of the target material. Using materials other than the factory-standard steel requires a specific calibration curve to correct for the resulting deviation in sensitivity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e: Secure the probe within a rigid bracket. The 60 mm case length requires adequate clearance behind the mounting point to accommodate the cable exit. Avoid overtightening mounting nuts to prevent structural deformation of the probe housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: The coaxial shield must be continuous through the ClickLoc connection. The system should be grounded at a single point, usually the Proximitor terminal block, to prevent ground loop currents from impacting signal stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Care\u003c\/strong\u003e: Inspect the ClickLoc interface for cleanliness before mating. An audible \"click\" confirms the connector is fully seated. In high-humidity environments, ensure the connector protector is engaged to prevent moisture-induced corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing\u003c\/strong\u003e: Adhere to a minimum static bend radius of 25.4 mm (1.0 inch). Avoid creating sharp bends or kinks in the coaxial cable, as these distort the internal geometry and affect signal propagation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53575972815032,"sku":"330173-00-06-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330103-00-03-10-02-00_f9da7d20-acc9-4a49-95fe-cf05ed4bf092.jpg?v=1781061407","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-330173-00-06-10-02-00-3300-5-mm-proximity-transducer","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}