{"product_id":"bently-nevada-330180-51-05-5-8mm-proximitor-sensor-24v-dc","title":"Bently Nevada 330180-51-05 5\/8mm Proximitor Sensor 24v-Dc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330180-51-05\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL 8 mm Proximitor Sensor\u003c\/strong\u003e with \u003cstrong\u003emultiple hazardous area approvals\u003c\/strong\u003e (CSA, ATEX, IECEx). Identical in electrical performance to the 330180-51-00, this model adds comprehensive safety certifications for use in explosive atmospheres.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada (Baker Hughes)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e 3300 XL 8 mm Proximity Transducer System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Proximitor Sensor (Signal Conditioner)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length:\u003c\/strong\u003e 5.0 meters (16.4 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Option:\u003c\/strong\u003e DIN rail mount (51)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e Multiple approvals (05) — CSA, ATEX, IECEx\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Compatibility:\u003c\/strong\u003e 3300 XL 8 mm proximity probes and 3300 XL extension cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 7.87 V\/mm (200 mV\/mil) nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e 2.0 mm (80 mils)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e -17.5 Vdc to -26 Vdc, max 12 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resistance:\u003c\/strong\u003e 50 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Sensitivity:\u003c\/strong\u003e \u0026lt; 2 mV change per volt input change\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e 0 to 10 kHz typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -52°C to +100°C (-62°F to +212°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -52°C to +105°C (-62°F to +221°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 100% condensing, non-submersible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e A308 aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Gold-plated brass \/ beryllium copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~246 g (8.7 oz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (TH35-15 or TH35-7.5 per IEC 60715)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e API 670 (4th Edition)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e Verify the installation area classification matches the sensor's approval ratings (CSA, ATEX, IECEx). Install per local hazardous area wiring codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap onto a 35 mm DIN rail (TH35-15 or TH35-7.5). Ensure the mounting location is within the approved temperature range and protected from direct exposure to explosive atmospheres if not rated for direct exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect \u003cstrong\u003e-17.5 Vdc to -26 Vdc\u003c\/strong\u003e. Max current: \u003cstrong\u003e12 mA\u003c\/strong\u003e. With intrinsic safety barriers: \u003cstrong\u003e-23 Vdc to -26 Vdc\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety:\u003c\/strong\u003e When used in hazardous areas, install appropriate intrinsic safety barriers between the sensor and the monitoring system. Verify barrier compatibility with the sensor's entity parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe \u0026amp; Cable:\u003c\/strong\u003e Connect the 3300 XL 8 mm probe and extension cable. Total system length must equal \u003cstrong\u003e5.0 meters\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Wiring:\u003c\/strong\u003e Route shielded cables to the monitoring system. Ground the shield at the monitoring system end only to prevent ground loops in hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Calibration:\u003c\/strong\u003e Set probe-to-target gap to approximately \u003cstrong\u003e1.27 mm (50 mils)\u003c\/strong\u003e. Verify linear output range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Retain all hazardous area certificates and installation instructions for regulatory inspections.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What approvals does the 330180-51-05 carry?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e-05\u003c\/strong\u003e suffix indicates \u003cstrong\u003emultiple approvals\u003c\/strong\u003e including CSA (US and Canada), ATEX (European), and IECEx (international). Specific approval markings are printed on the sensor label. Refer to the official datasheet for complete approval details and entity parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this sensor in a Zone 0 area?\u003c\/strong\u003e\u003cbr\u003eA: The 330180-51-05 is approved for use with appropriate intrinsic safety barriers. Verify the specific Ex rating (e.g., Ex ia IIC T4) on the sensor label against your area classification requirements. Consult the official hazardous area certificate for detailed installation conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 330180-51-00 and 330180-51-05?\u003c\/strong\u003e\u003cbr\u003eA: The only difference is the \u003cstrong\u003eagency approval option\u003c\/strong\u003e. The \u003cstrong\u003e-51-00\u003c\/strong\u003e has no approvals; the \u003cstrong\u003e-51-05\u003c\/strong\u003e has CSA, ATEX, and IECEx approvals. Electrical and mechanical specifications are identical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is intrinsic safety barrier required?\u003c\/strong\u003e\u003cbr\u003eA: Yes, when installed in hazardous areas. The sensor must be connected through approved intrinsic safety barriers. The barrier must be compatible with the sensor's entity parameters (voltage, current, capacitance, inductance).\u003c\/p\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlways verify your plant's \u003cstrong\u003ehazardous area classification\u003c\/strong\u003e before selecting the approval option. The \u003cstrong\u003e-05\u003c\/strong\u003e suffix covers most North American and European requirements.\u003c\/li\u003e\n\u003cli\u003eFor country-specific approvals (e.g., China), look for \u003cstrong\u003e-CN\u003c\/strong\u003e suffix variants.\u003c\/li\u003e\n\u003cli\u003eWhen replacing a sensor in a hazardous area, \u003cstrong\u003enever downgrade\u003c\/strong\u003e from an approved model to a non-approved model — this violates safety regulations.\u003c\/li\u003e\n\u003cli\u003eEnsure intrinsic safety barriers are \u003cstrong\u003eproperly rated\u003c\/strong\u003e for the sensor's electrical parameters and the area classification.\u003c\/li\u003e\n\u003cli\u003eKeep hazardous area certificates on file for audits and inspections. Certificates are available from Bently Nevada upon request.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53797691490488,"sku":"330180-51-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330180-51-00r180.png?v=1784701515","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-330180-51-05-5-8mm-proximitor-sensor-24v-dc","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}