{"product_id":"bently-nevada-330180-90-00-3300-xl-8-mm-proximitor-sensor","title":"Bently Nevada 330180-90-00 3300 XL 8 mm Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330180-90-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL 8 mm Proximitor Sensor\u003c\/strong\u003e configured for a \u003cstrong\u003e9.0 meter system length\u003c\/strong\u003e with \u003cstrong\u003epanel mounting\u003c\/strong\u003e and \u003cstrong\u003eno agency approvals\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada (Baker Hughes)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e 3300 XL 8 mm Proximity Transducer System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Proximitor Sensor (Signal Conditioner)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length:\u003c\/strong\u003e 9.0 meters (29.5 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Option:\u003c\/strong\u003e Panel mount (90)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e Not required (00)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Compatibility:\u003c\/strong\u003e 3300 XL 8 mm proximity probes and 3300 XL extension cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e 7.87 V\/mm (200 mV\/mil) nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e 2.0 mm (80 mils)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e -17.5 Vdc to -26 Vdc, max 12 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resistance:\u003c\/strong\u003e 50 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Sensitivity:\u003c\/strong\u003e \u0026lt; 2 mV change per volt input change\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e 0 to 10 kHz typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -52°C to +100°C (-62°F to +212°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -52°C to +105°C (-62°F to +221°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 100% condensing, non-submersible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e A308 aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Gold-plated brass \/ beryllium copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~246 g (8.7 oz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Panel mount (4-hole footprint, matching legacy designs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e API 670 (4th Edition)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the sensor to the panel using the four-hole mounting pattern. Use appropriate hardware (screws, washers, lock washers) to prevent loosening from vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect \u003cstrong\u003e-17.5 Vdc to -26 Vdc\u003c\/strong\u003e. Max current: \u003cstrong\u003e12 mA\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe \u0026amp; Extension Cable:\u003c\/strong\u003e Connect the 3300 XL 8 mm probe and extension cable. Total system length must equal \u003cstrong\u003e9.0 meters\u003c\/strong\u003e (probe + cable combined).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Wiring:\u003c\/strong\u003e Connect shielded output cables to the monitoring system. Ground shield at the monitoring system end.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Calibration:\u003c\/strong\u003e Set probe-to-target gap to approximately \u003cstrong\u003e1.27 mm (50 mils)\u003c\/strong\u003e. Verify output is within the linear range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the 9-meter cable away from high-voltage power cables and motor drives. Maintain minimum separation of \u003cstrong\u003e300 mm\u003c\/strong\u003e from AC power lines.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 330180-90-00 and 330180-91-00?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e330180-90-00\u003c\/strong\u003e is \u003cstrong\u003epanel mount\u003c\/strong\u003e with no approvals. The \u003cstrong\u003e330180-91-00\u003c\/strong\u003e is \u003cstrong\u003eDIN rail mount\u003c\/strong\u003e with no approvals. Both are 9.0 meter system length. Choose based on your cabinet mounting preference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use a 5-meter cable with this sensor?\u003c\/strong\u003e\u003cbr\u003eA: No. The \u003cstrong\u003e330180-90-00\u003c\/strong\u003e is calibrated for \u003cstrong\u003e9.0 meters total system length\u003c\/strong\u003e. Using a 5-meter cable will result in incorrect sensitivity. For 5-meter systems, order \u003cstrong\u003e330180-50-00\u003c\/strong\u003e or \u003cstrong\u003e330180-51-00\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the panel mount footprint compatible with 7200-series sensors?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The 3300 XL panel mount Proximitor Sensors are designed with a mounting footprint that matches legacy 7200-series sensors, facilitating direct replacement without drilling new holes.\u003c\/p\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure the \u003cstrong\u003etotal distance\u003c\/strong\u003e from the probe mounting location to the monitoring cabinet. Add \u003cstrong\u003e20% margin\u003c\/strong\u003e for routing. Order 5.0 m or 9.0 m accordingly.\u003c\/li\u003e\n\u003cli\u003eChoose \u003cstrong\u003epanel mount (-90- or -50-)\u003c\/strong\u003e for high-vibration environments or when matching legacy mounting patterns. Choose \u003cstrong\u003eDIN rail mount (-91- or -51-)\u003c\/strong\u003e for modern cabinet designs.\u003c\/li\u003e\n\u003cli\u003eFor hazardous areas, select \u003cstrong\u003e-05\u003c\/strong\u003e approval suffix instead of \u003cstrong\u003e-00\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWhen upgrading from 7200-series, replace all components (probe, cable, Proximitor) with 3300 XL equivalents. Do not mix series.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53797695881400,"sku":"330180-90-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/330180-12-00r270.png?v=1782726963","url":"https:\/\/www.globalpetroparts.com\/products\/bently-nevada-330180-90-00-3300-xl-8-mm-proximitor-sensor","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}