{"product_id":"bmxdra1605-schneider-modicon-quantum-x80-discrete-output-module","title":"BMXDRA1605 Schneider Modicon Quantum X80 Discrete Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBMXDRA1605\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-density relay output interface for the Schneider Electric Modicon X80 platform. This module provides 16 independent Normally Open (NO) relay channels, allowing the PLC to control a diverse range of field devices across varying voltage levels, from 24V DC to 240V AC. It integrates seamlessly into M340 and M580 architectures, offering a robust mechanical switching solution for applications requiring galvanic isolation between the controller and the load. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure maximum electrical life and system uptime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay (Normally Open)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range (DC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 V to 30 V DC (24 V nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range (AC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 V to 264 V AC (240 V nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Current (Ith)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eActivation: \u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e 8 ms \/ Deactivation: \u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e 10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Switching Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mA at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 10 MOhm at 500 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMTBF Reliability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,357,810 Hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 V AC at 50\/60 Hz for 1 minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Voltage Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe relay architecture allows the BMXDRA1605 to switch both AC and DC loads on the same module. This eliminates the need for separate digital output modules for different power requirements, significantly reducing cabinet hardware costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides a 2000V AC dielectric strength between the internal logic and the output circuits. This physical separation prevents field-side electrical surges from damaging the expensive PLC processor or backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA comprehensive LED array provides real-time status updates. A green RUN LED indicates module health, while individual green LEDs per channel show output status. Red ERR and I\/O LEDs instantly signal internal faults or configuration mismatches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for harsh industrial zones, the module withstands 30 gn shock and 3 gn vibration. The TC protective treatment allows the module to operate reliably in humid environments (up to 95% RH) without performance degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the BMXDRA1605 include internal fuse protection?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. To protect the relay contacts from short circuits or overloads, you must install one fast-blow fuse per channel or group of channels as part of your external wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for high-frequency switching?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelay modules have mechanical limitations. For high-speed switching applications, consider a solid-state transistor output module. The BMXDRA1605 is best suited for standard interposing relay or actuator control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat external protection do I need for inductive loads?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor DC loads, install a discharge diode across each output. For AC loads, utilize an RC circuit or a ZNO surge limiter to prevent contact arcing and extend the electrical durability of the relay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum operating altitude for this module?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module operates at full specification up to 2000 meters. For installations between 2000 and 5000 meters, apply the appropriate derating factors as specified by Schneider Electric documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53413614223544,"sku":"BMXDRA1605","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/BMXDRA1605_1.jpg?v=1777346298","url":"https:\/\/www.globalpetroparts.com\/products\/bmxdra1605-schneider-modicon-quantum-x80-discrete-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}