{"product_id":"bmxxbp1002-schneider-modicon-10-slot-ethernet-backplane","title":"BMXXBP1002 | Schneider Modicon | 10-slot Ethernet Backplane","description":"\u003ch3\u003eSchneider Electric BMEXBP1002 Modicon M580 10-Slot Dual Power Supply Ethernet + X-bus Backplane — Redundant PS, 8 Ethernet + 2 X-bus Slots\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBMEXBP1002\u003c\/strong\u003e (note: correct spelling is \u003cstrong\u003eBMEXBP1002\u003c\/strong\u003e, not BMXXBP1002) is a \u003cstrong\u003e10-slot dual power supply Ethernet + X-bus backplane\u003c\/strong\u003e for Schneider Electric's \u003cstrong\u003eModicon M580\u003c\/strong\u003e automation platform. It features \u003cstrong\u003e2 dedicated redundant power supply slots\u003c\/strong\u003e (CPS1\/CPS2) and \u003cstrong\u003e10 module slots\u003c\/strong\u003e (8 with dual Ethernet + X-bus connectivity, 2 with X-bus only), enabling high-availability architectures with redundant power and integrated Ethernet switching for distributed I\/O and peer-to-peer communication.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon M580 \/ Modicon X80\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Dual Power Supply Ethernet + X-bus Backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Slots:\u003c\/strong\u003e 10 total (8 Ethernet + X-bus + 2 X-bus only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Slots:\u003c\/strong\u003e 2 dedicated slots (CPS1 and CPS2) for BMXCPS4002● redundant power supply only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Slots:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e8 slots with \u003cstrong\u003edual Ethernet + X-bus connectors\u003c\/strong\u003e for mixed modules (processors, I\/O, communication, application-specific)\u003c\/li\u003e\n\u003cli\u003e2 slots with \u003cstrong\u003eX-bus only connectors\u003c\/strong\u003e for X-bus modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3.9 W (251 mW at 3.3 VDC + 3.9 W at 24 VDC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 76 mA at 3.3 VDC; 162 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF Reliability:\u003c\/strong\u003e 1,700,000 hours (1,184,170 hours per some sources)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Connector:\u003c\/strong\u003e 1 × XBE connector for X-bus backplane expansion (multirack configuration)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e35 mm symmetrical DIN rail (by clips)\u003c\/li\u003e\n\u003cli\u003ePanel mount (4 screws, diameter 4.32–6.35 mm \/ 0.17–0.25 in)\u003c\/li\u003e\n\u003cli\u003eMounting plate (4 × M6 screws)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 22.40 × 6.22 × 2.72 in (569 × 158 × 69 mm) package; backplane dimensions per standard X80 format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.37 kg (3.02 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Weight:\u003c\/strong\u003e 1.355 kg (2.99 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5–95% without condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Treatment:\u003c\/strong\u003e TC (Technical Coating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirectives:\u003c\/strong\u003e 2014\/35\/EU (Low Voltage), 2014\/30\/EU (EMC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Compatibility:\u003c\/strong\u003e BMEP58\/BMEH58 processors, BMXCPS4002 power supply, I\/O modules, specific application modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e Yes — dual redundant power supplies (BMXCPS4002●) and redundant processors (BMEH58●●40)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Connection:\u003c\/strong\u003e 2 attachment points for mounting the shielding connection bar (BMXXSP●●●)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Screw:\u003c\/strong\u003e Integrated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Status:\u003c\/strong\u003e Compliant since 1623 (week 23, 2016)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACh Status:\u003c\/strong\u003e Reference containing SVHC above threshold — consult CaP for details\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGreen Premium:\u003c\/strong\u003e Yes (Mercury Free)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 18 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e Active \/ In production\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eArchitecture \u0026amp; Functionality\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Bus Backplane:\u003c\/strong\u003e Integrates both Ethernet and X-bus on the same backplane, eliminating separate communication modules for Ethernet connectivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Ethernet Switch:\u003c\/strong\u003e The Ethernet backplane includes an embedded switch connected to multiple slots, enabling direct Ethernet communication for M580 CPUs and Ethernet-capable I\/O modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Power Supply Support:\u003c\/strong\u003e Two dedicated CPS slots accept BMXCPS4002● redundant power supplies for N+1 power redundancy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Availability Architectures:\u003c\/strong\u003e Supports Hot Standby redundant processors (BMEH58●●40) with 1 Gbps fiber optic or copper link\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpansion Capability:\u003c\/strong\u003e XBE connector allows connection of BMXXBE1000 backplane expander for multirack systems (up to 7 expansion racks, 30m total distance)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Connection Kit:\u003c\/strong\u003e Compatible with BMXXSP●●● 90° cable shielding connection kits for EMC compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Flexibility:\u003c\/strong\u003e 8 dual-bus slots support any Ethernet + X-bus module; 2 X-bus-only slots support standard X80 modules without Ethernet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated Backplane Models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP0400:\u003c\/strong\u003e 4-slot standard Ethernet + X-bus backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP0800:\u003c\/strong\u003e 8-slot standard Ethernet + X-bus backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP1200:\u003c\/strong\u003e 12-slot standard Ethernet + X-bus backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP0602:\u003c\/strong\u003e 6-slot dual power supply Ethernet + X-bus backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP1002:\u003c\/strong\u003e 10-slot dual power supply Ethernet + X-bus backplane (this product)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP0400H:\u003c\/strong\u003e 4-slot ruggedized Ethernet + X-bus backplane (-25°C to +70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP0800H:\u003c\/strong\u003e 8-slot ruggedized Ethernet + X-bus backplane (-25°C to +70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP1200H:\u003c\/strong\u003e 12-slot ruggedized Ethernet + X-bus backplane (-25°C to +70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP0602H:\u003c\/strong\u003e 6-slot ruggedized dual power supply backplane (-25°C to +70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMEXBP1002H:\u003c\/strong\u003e 10-slot ruggedized dual power supply backplane (-25°C to +70°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBMXXBP0400\/0600\/0800\/1200:\u003c\/strong\u003e X-bus only backplanes (M340\/M580 compatible, no Ethernet)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the BMEXBP1002 on a \u003cstrong\u003e35 mm symmetrical DIN rail\u003c\/strong\u003e or panel using 4 screws (4.32–6.35 mm diameter) or 4 × M6 screws for mounting plate.\u003c\/li\u003e\n\u003cli\u003eInstall \u003cstrong\u003etwo BMXCPS4002● redundant power supplies\u003c\/strong\u003e in the dedicated CPS1 and CPS2 slots (leftmost positions).\u003c\/li\u003e\n\u003cli\u003eInstall the \u003cstrong\u003eBMEP58\/BMEH58 processor module\u003c\/strong\u003e in slot 0 (must be in the main rack, not expansion).\u003c\/li\u003e\n\u003cli\u003eInstall \u003cstrong\u003eI\/O modules, communication modules, and application-specific modules\u003c\/strong\u003e in the remaining 8 dual-bus slots or 2 X-bus-only slots.\u003c\/li\u003e\n\u003cli\u003eConnect \u003cstrong\u003eEthernet cables\u003c\/strong\u003e (Cat 5e\/6) to the embedded switch ports for distributed I\/O (EIO) and peer-to-peer communication.\u003c\/li\u003e\n\u003cli\u003eFor multirack systems, connect \u003cstrong\u003eBMXXBE1000 backplane expander\u003c\/strong\u003e to the XBE connector on the right side.\u003c\/li\u003e\n\u003cli\u003eInstall \u003cstrong\u003eBMXXSP●●● shielding connection kit\u003c\/strong\u003e at the attachment points for EMC compliance.\u003c\/li\u003e\n\u003cli\u003eConnect \u003cstrong\u003egrounding screw\u003c\/strong\u003e to panel earth.\u003c\/li\u003e\n\u003cli\u003ePower on and verify module status via \u003cstrong\u003eEcoStruxure Control Expert\u003c\/strong\u003e diagnostics.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the correct model BMXXBP1002 or BMEXBP1002?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eBMEXBP1002\u003c\/strong\u003e is the correct spelling. \u003cstrong\u003eBMXXBP\u003c\/strong\u003e series are \u003cstrong\u003eX-bus only\u003c\/strong\u003e backplanes (BMXXBP0400\/0600\/0800\/1200). \u003cstrong\u003eBMEXBP\u003c\/strong\u003e series are \u003cstrong\u003eEthernet + X-bus dual bus\u003c\/strong\u003e backplanes for M580 (BMEXBP0400\/0800\/1200\/0602\/1002). The \"E\" in BMEXBP stands for Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use a standard power supply in the dual power supply slots?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e The CPS1 and CPS2 slots are \u003cstrong\u003eonly compatible with BMXCPS4002● redundant power supplies\u003c\/strong\u003e. Standard power supplies (BMXCPS2000\/2010\/3500\/3540) cannot be installed in these dedicated slots. However, a single BMXCPS4002● can be used in a standard backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many Ethernet ports does each slot have?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e8 dual-bus slots\u003c\/strong\u003e each have \u003cstrong\u003e2 Ethernet connectors\u003c\/strong\u003e (for ring or daisy-chain topology) plus the X-bus connector. The \u003cstrong\u003e2 X-bus-only slots\u003c\/strong\u003e have no Ethernet connectivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is BMEXBP1002 compatible with M340?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; \u003cstrong\u003ePartially.\u003c\/strong\u003e M340 processors (BMXP34) can be installed in BMEXBP backplanes but \u003cstrong\u003ecannot use the Ethernet connectivity\u003c\/strong\u003e — they only communicate via X-bus. For full Ethernet functionality, use M580 processors (BMEP58\/BMEH58).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum number of expansion racks?\u003c\/strong\u003e\u003cbr\u003eA: Up to \u003cstrong\u003e7 expansion racks\u003c\/strong\u003e with a cumulative distance of \u003cstrong\u003e30 meters\u003c\/strong\u003e (98 ft) using BMXXBE1000 expanders and X-bus cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between BMEXBP1002 and BMEXBP1002H?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eBMEXBP1002\u003c\/strong\u003e is the \u003cstrong\u003estandard version\u003c\/strong\u003e (0°C to +60°C). \u003cstrong\u003eBMEXBP1002H\u003c\/strong\u003e is the \u003cstrong\u003eruggedized version\u003c\/strong\u003e with extended temperature range (-25°C to +70°C) and enhanced environmental resistance.\u003c\/p\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580, 4-slot Ethernet + X-bus:\u003c\/strong\u003e BMEXBP0400 \/ BMEXBP0400H (ruggedized)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580, 8-slot Ethernet + X-bus:\u003c\/strong\u003e BMEXBP0800 \/ BMEXBP0800H (ruggedized)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580, 12-slot Ethernet + X-bus:\u003c\/strong\u003e BMEXBP1200 \/ BMEXBP1200H (ruggedized)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580, 6-slot dual PS Ethernet + X-bus:\u003c\/strong\u003e BMEXBP0602 \/ BMEXBP0602H (ruggedized)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM580, 10-slot dual PS Ethernet + X-bus:\u003c\/strong\u003e BMEXBP1002 \/ BMEXBP1002H (ruggedized)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM340\/M580, X-bus only:\u003c\/strong\u003e BMXXBP0400\/0600\/0800\/1200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlways verify:\u003c\/strong\u003e Processor type (M340 vs M580), redundancy requirements, temperature range, and Ethernet connectivity needs before ordering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder redundant power supplies:\u003c\/strong\u003e BMXCPS4002 (standard) or BMXCPS4002H (ruggedized) for dual PS backplanes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder shielding kit:\u003c\/strong\u003e BMXXSP0800 or BMXXSP1000 for proper EMC compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53759103566008,"sku":"BMXXBP1002","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/BMXXBP1002.png?v=1783925836","url":"https:\/\/www.globalpetroparts.com\/products\/bmxxbp1002-schneider-modicon-10-slot-ethernet-backplane","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}