{"product_id":"bmxxbp1002-schneider-modicon-8-channel-analog-safety-input-module","title":"BMXXBP1002 | Schneider Modicon | 8-Channel Analog Safety Input Module","description":"\u003ch3\u003eSchneider Electric 140SAI94000S Modicon Quantum Analog Input Module — 16-Channel, 4–20mA, HART Compatible\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e140SAI94000S\u003c\/strong\u003e is a \u003cstrong\u003e16-channel analog current input module\u003c\/strong\u003e for Schneider Electric's \u003cstrong\u003eModicon Quantum\u003c\/strong\u003e automation platform. It accepts \u003cstrong\u003e4–20 mA current loop signals\u003c\/strong\u003e from field transmitters and sensors, with \u003cstrong\u003eHART protocol compatibility\u003c\/strong\u003e for smart device communication. The module provides \u003cstrong\u003eper-channel isolation\u003c\/strong\u003e, comprehensive diagnostics, and high-resolution A\/D conversion for precise process control applications.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon Quantum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Analog Input Module (Current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 single-ended inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e 4–20 mA (standard); 0–20 mA (configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 250 Ω (standard for 4–20 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit A\/D conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.15% of full scale (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 10 ms per channel (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Per-channel galvanic isolation (channel-to-channel and channel-to-bus)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Compatibility:\u003c\/strong\u003e Yes — supports HART protocol communication over 4–20 mA loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Protection:\u003c\/strong\u003e Overvoltage, reverse polarity, surge protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Current Required:\u003c\/strong\u003e 400 mA typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 4.5 W typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Requirement:\u003c\/strong\u003e 16 input words\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Active (green), F (red — external fault), per-channel status LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Quantum backplane slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 27 × 10 × 4.5 cm (L × W × H) [standard Quantum module format]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.45 kg (0.99 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus:\u003c\/strong\u003e Active \/ In production\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eArchitecture \u0026amp; Functionality\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Channel Design:\u003c\/strong\u003e Each channel independently configurable for 4–20 mA or 0–20 mA input range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Protocol Support:\u003c\/strong\u003e Enables digital communication with smart transmitters for remote configuration, diagnostics, and multivariable data access over the existing 4–20 mA analog loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-Channel Isolation:\u003c\/strong\u003e Galvanic isolation protects the PLC from field-side ground loops and electrical noise\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e 16-bit A\/D converter provides precise measurement for critical process control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Update Rate:\u003c\/strong\u003e 10 ms per channel ensures responsive control for fast-changing process variables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e Open wire detection, overrange\/underrange detection, and HART device status monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Protection:\u003c\/strong\u003e Built-in protection against overvoltage, reverse polarity connection, and surge transients\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the 140SAI94000S into a \u003cstrong\u003estandard I\/O slot\u003c\/strong\u003e on the Quantum backplane.\u003c\/li\u003e\n\u003cli\u003eConnect \u003cstrong\u003e4–20 mA field transmitters\u003c\/strong\u003e to the module terminals using shielded twisted-pair cable.\u003c\/li\u003e\n\u003cli\u003eEnsure \u003cstrong\u003eshield grounding\u003c\/strong\u003e at one end only to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eFor \u003cstrong\u003eHART devices\u003c\/strong\u003e, connect HART communicator or asset management software to the loop.\u003c\/li\u003e\n\u003cli\u003eConfigure \u003cstrong\u003einput range, filtering, and HART parameters\u003c\/strong\u003e via Unity Pro or Concept programming software.\u003c\/li\u003e\n\u003cli\u003ePower on and verify \u003cstrong\u003eActive LED\u003c\/strong\u003e (green) and channel status LEDs.\u003c\/li\u003e\n\u003cli\u003eMonitor \u003cstrong\u003eF LED\u003c\/strong\u003e (red) for external fault indication.\u003c\/li\u003e\n\u003cli\u003eCalibrate channels as required for your specific application.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 140SAI94000 and 140SAI94000S?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003e140SAI94000\u003c\/strong\u003e is the base version. \u003cstrong\u003e140SAI94000S\u003c\/strong\u003e is the \u003cstrong\u003eS-version\u003c\/strong\u003e with firmware updates or component enhancements. Both are functionally compatible; the S-version may include improved HART compatibility or diagnostic features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does 140SAI94000S support HART protocol?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eYes.\u003c\/strong\u003e The module is HART-compatible, enabling digital communication with smart transmitters over the 4–20 mA analog loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum number of HART devices per module?\u003c\/strong\u003e\u003cbr\u003eA: Up to \u003cstrong\u003e16 HART devices\u003c\/strong\u003e (one per channel) can be connected simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use 140SAI94000S with voltage signals (0–10V, ±10V)?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e 140SAI94000S is a \u003cstrong\u003ecurrent input module\u003c\/strong\u003e (4–20 mA \/ 0–20 mA) only. For voltage inputs, use \u003cstrong\u003e140AVI03000\u003c\/strong\u003e (8-channel voltage input) or \u003cstrong\u003e140ACI03000\u003c\/strong\u003e (16-channel current\/voltage input).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is 140SAI94000S compatible with M580?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e 140SAI94000S is designed for \u003cstrong\u003eModicon Quantum\u003c\/strong\u003e racks. M580 uses different analog input modules (e.g., BMXAMI0810).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What wire type is recommended?\u003c\/strong\u003e\u003cbr\u003eA: Use \u003cstrong\u003eshielded twisted-pair cable\u003c\/strong\u003e (typically #18–#22 AWG) for 4–20 mA signals. Ground the shield at one end only (typically at the panel ground).\u003c\/p\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantum, 16-channel 4–20mA, HART:\u003c\/strong\u003e 140SAI94000S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantum, 16-channel 4–20mA, no HART:\u003c\/strong\u003e 140ACI03000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantum, 8-channel voltage (±10V):\u003c\/strong\u003e 140AVI03000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantum, 8-channel RTD\/TC:\u003c\/strong\u003e 140ARI03010\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlways verify:\u003c\/strong\u003e Signal type (current vs voltage), HART requirement, channel count, and isolation needs before ordering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder compatible terminal block:\u003c\/strong\u003e 140XTS00200 screw terminal block (40 contacts, ordered separately)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor HART applications:\u003c\/strong\u003e Ensure HART communicator or asset management software is available\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53759496126648,"sku":"140SAI94000S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/140SAI94000S_2.png?v=1783925861","url":"https:\/\/www.globalpetroparts.com\/products\/bmxxbp1002-schneider-modicon-8-channel-analog-safety-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}