{"product_id":"cc-paoh01-51405039-175-honeywell-analog-output-module","title":"CC-PAOH01 51405039-175 | Honeywell Analog Output Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAOH01 is a 16-channel High-Level Analog Output Module with HART capability designed for the Experion Series C I\/O platform. It delivers high-level constant 4-20 mA current loops to control actuators, positioners, and recording\/indicating field devices, featuring extensive self-diagnostics and per-channel safe-state behaviors.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProduct Type: High-Level Analog Output with HART (16-point)\u003c\/li\u003e\n  \u003cli\u003eModel: CC-PAOH01\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n  \u003cli\u003eDocument Reference: Experion Series-C I\/O Specification, EP03-490-520 (Version 1.5)\u003c\/li\u003e\n  \u003cli\u003eOutput Channels: 16\u003c\/li\u003e\n  \u003cli\u003eOutput Type: 4-20 mA DC current loop\u003c\/li\u003e\n  \u003cli\u003eDirectly Settable Output Current Range: 0 mA, 2.9 mA to 21.1 mA\u003c\/li\u003e\n  \u003cli\u003eResolution: ± 0.05% of Full Scale\u003c\/li\u003e\n  \u003cli\u003eCalibrated Accuracy: ± 0.35% of Full Scale (at 25 °C) including linearity\u003c\/li\u003e\n  \u003cli\u003eOutput Current Linearity: ± 0.05% of Full Scale nominal\u003c\/li\u003e\n  \u003cli\u003eOutput Temperature Drift: 0.005% of Full Scale\/°C\u003c\/li\u003e\n  \u003cli\u003eOutput Readback Accuracy: ±4% of Full Scale\u003c\/li\u003e\n  \u003cli\u003eOutput Ripple: \u0026lt; 100 mV peak-to-peak at power line frequency (across 250 Ω load)\u003c\/li\u003e\n  \u003cli\u003eMaximum Resistive Load: 800 ohms (with 24 V supply ranging from 22 VDC through 28 VDC)\u003c\/li\u003e\n  \u003cli\u003eMaximum Output Compliant Voltage: 16 V (with 24 V supply ranging from 22 VDC through 28 VDC)\u003c\/li\u003e\n  \u003cli\u003eMaximum Open Circuit Voltage: 22 V\u003c\/li\u003e\n  \u003cli\u003eResponse Time (DAC Input Code to Output): Settles to within 1% of final value within 80 ms\u003c\/li\u003e\n  \u003cli\u003eRedundancy Switchover Gap (0 mA Output to Field): 10 ms maximum (applies to Redundancy only)\u003c\/li\u003e\n  \u003cli\u003eHART Capabilities: Supports multivariable instruments with multiple modems for fast collection of control variables\u003c\/li\u003e\n  \u003cli\u003eRedundancy Support: Optional (via specific Redundant IOTAs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatible Module Termination Assemblies (IOTA Models)\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TAOX01:\u003c\/strong\u003e Non-Redundant 6” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-TAOX11:\u003c\/strong\u003e Redundant 12” IOTA assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GAOX11:\u003c\/strong\u003e Redundant 12” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCC-GAOX21:\u003c\/strong\u003e Non-Redundant 6” IOTA assembly (Conformally Coated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFAILOPT Behavior:\u003c\/strong\u003e Supports configurable fail-option parameters defined on a per-channel basis. Each channel can be set to either \u003cem\u003eHOLD LAST VALUE\u003c\/em\u003e or \u003cem\u003eSHED to a SAFE VALUE\u003c\/em\u003e. If the IOM device electronics fail completely, the output always drops to 0 mA (the absolute safe state).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpen-wire Detection:\u003c\/strong\u003e Automatically scans, detects, and annunciates open field wiring conditions via a Channel Soft Failure indication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Read-back:\u003c\/strong\u003e Continuously monitors executed output values and generates system alarms upon tracking discrepancy detections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-incendive Output:\u003c\/strong\u003e Provides built-in non-incendive field circuit capability for deployment near hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInsert the CC-PAOH01 module onto its matched IOTA slot allocation (CC-TAOX01, CC-TAOX11, CC-GAOX11, or CC-GAOX21) depending on redundancy and environmental protection requirements.\u003c\/li\u003e\n  \u003cli\u003eEnsure that total external field loop loop resistance, including wire resistance and control valve positioner internal load, does not exceed the 800 Ω maximum threshold.\u003c\/li\u003e\n  \u003cli\u003eVerify that the maximum open circuit voltage stays bounded at 22 V under full diagnostic loops testing.\u003c\/li\u003e\n  \u003cli\u003eDefine individual channel FAILOPT behaviors (Hold Last Value or Safe Value target) inside the control network manager environment before executing C300 controller warm boot sequences.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53617727602872,"sku":"51405039-175","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/CC-PAOH01_3.png?v=1782201392","url":"https:\/\/www.globalpetroparts.com\/products\/cc-paoh01-51405039-175-honeywell-analog-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}