{"product_id":"central-processor-module-hima-f8628x-f-8628x","title":"Central Processor Module HIMA F8628X F 8628X","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA F 8628X (F8628X)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the pinnacle of processing power for the HIMax safety platform. As a high-performance central processing unit, it manages complex safety-critical logic for large-scale industrial applications, including Emergency Shutdown (ESD), Fire and Gas (F\u0026amp;G) detection, and Burner Management Systems (BMS). The F 8628X utilizes a multi-processor architecture to execute parallel logic paths, ensuring absolute determinism and millisecond response times. By integrating this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal processor into your HIMax architecture, you secure a SIL 3 certified control environment capable of managing up to thousands of I\/O points without compromising system throughput.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe F 8628X utilizes advanced safe-core technology and high-speed communication backplanes to maintain total system integrity:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eF 8628X \/ F8628X\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHIMA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHIMax\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSIL 3 (IEC 61508), PL e (EN ISO 13849-1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecialized multi-core safety processor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-capacity non-volatile Flash and ECC RAM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated safeethernet (100 Mbit\/s) and internal bus interfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC (Nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 60 deg C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Coverage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 99 percent internal diagnostic depth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-segment LED display for system status and fault codes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe HIMA F 8628X provides superior architectural solutions for complex industrial safety loops:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Stop Operation (X-Generation):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F 8628X supports the \"X-Generation\" philosophy, allowing for online modifications and hardware swaps without interrupting the safety function. This eliminates the need for plant shutdowns during CPU upgrades or maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Network Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module manages safeethernet protocols directly, allowing for the seamless synchronization of distributed HIMax racks across a plant-wide network while maintaining SIL 3 signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Cybersecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CPU hardware incorporates a \"locked\" operating system and restricted access ports. This prevents unauthorized firmware changes and protects the safety logic from external cyber interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Fault forensics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module stores detailed diagnostic data and sequence-of-event (SOE) logs locally. This allows engineers to rapidly pinpoint the root cause of a trip, significantly reducing downtime during post-event analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the F 8628X in a redundant configuration?\u003c\/strong\u003eYes. The HIMax architecture supports redundant CPU configurations where two F 8628X modules work in parallel. This setup provides maximum availability, ensuring the safety system remains operational even if one processor fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate memory card?\u003c\/strong\u003eThe F 8628X contains integrated high-speed memory for logic execution. However, specific project configurations may require a HIMA industrial SD card for external data logging or application backups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the F 8628X compatible with older H41q\/H51q modules?\u003c\/strong\u003eNo. The F 8628X is exclusive to the HIMax platform. It uses the modern HIMax backplane and safeethernet communication, which differ fundamentally from the legacy Planar4 or H-series architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is buying a Brand New F 8628X vital?\u003c\/strong\u003eHigh-speed safety processors are sensitive to heat and electrical stress over time. Refurbished units may contain latent defects in the silicon or degraded internal capacitors. Only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits guarantee the 20-year design life and safety certifications required for hazardous process industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":53441254588600,"sku":"F 8628X","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/F8628X_3.jpg?v=1778118381","url":"https:\/\/www.globalpetroparts.com\/products\/central-processor-module-hima-f8628x-f-8628x","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}