{"product_id":"channel-isolated-8-input-rtd-foxboro-i-a-series-fbm203-rh914sv","title":"Channel Isolated 8 Input RTD FOXBORO I\/A Series FBM203 RH914SV","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM203 RH914SV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eFoxboro\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eI\/A Series delivers precise RTD temperature measurement for industrial control systems.\u003cbr\u003eThis module provides eight isolated input channels, ensuring accurate thermal data acquisition across multiple field points.\u003c\/p\u003e\n\u003cp\u003eMoreover,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM203 RH914SV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports high-resolution temperature sensing, improving process stability in demanding industrial environments.\u003cbr\u003eEngineers choose this module because it ensures reliable performance and consistent measurement accuracy under harsh conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFBM203 RH914SV\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eFoxboro I\/A Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRTD Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated RTD input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensors\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt1000 RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-200°C to +850°C (sensor dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit high precision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Current\u003c\/td\u003e\n\u003ctd\u003eLow-level RTD excitation current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003e2-wire \/ 3-wire \/ 4-wire RTD support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e100 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Rejection\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz filtering supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eI\/A Series Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Processing\u003c\/td\u003e\n\u003ctd\u003eReal-time temperature conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eBackplane powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003eApprox. 17 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eI\/A Series baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003eApprox. 45 × 200 × 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators and self-test capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eFAQ\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the\u003cspan\u003e \u003c\/span\u003eFBM203 RH914SV\u003cspan\u003e \u003c\/span\u003emodule brand new and original?\u003c\/strong\u003e\u003cbr\u003eYes, all\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM203 RH914SV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules are brand new, original, and factory sealed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Do you have the\u003cspan\u003e \u003c\/span\u003eFBM203 RH914SV\u003cspan\u003e \u003c\/span\u003ein stock?\u003c\/strong\u003e\u003cbr\u003eYes, we keep\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM203 RH914SV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein stock and ready for immediate shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How fast can you ship the\u003cspan\u003e \u003c\/span\u003eFBM203 RH914SV?\u003c\/strong\u003e\u003cbr\u003eWe usually ship within 3 days to 2 weeks, depending on order size and availability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Which logistics services do you use for delivery?\u003c\/strong\u003e\u003cbr\u003eWe commonly use DHL and other reliable international courier services.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What is the return policy for\u003cspan\u003e \u003c\/span\u003eFBM203 RH914SV?\u003c\/strong\u003e\u003cbr\u003eWe support returns within 30 days if any verified quality issue occurs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What type of sensors does the\u003cspan\u003e \u003c\/span\u003eFBM203 RH914SV\u003cspan\u003e \u003c\/span\u003esupport?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFBM203 RH914SV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports PT100 and PT1000 RTD sensors for industrial temperature measurement applications.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53371116257464,"sku":"FBM203 RH914SV","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FBM203RH914SV_3.jpg?v=1776652620","url":"https:\/\/www.globalpetroparts.com\/products\/channel-isolated-8-input-rtd-foxboro-i-a-series-fbm203-rh914sv","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}