{"product_id":"di830-abb-3bse013210r1-16-channel-digital-input-module","title":"DI830 ABB 3BSE013210R1 16-Channel Digital Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB DI830 (3BSE013210R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density 16-channel Digital Input (DI) module within the S800 I\/O system. This module captures discrete signals from field devices such as pushbuttons, limit switches, and relay contacts. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring high-integrity data acquisition for AC 800M controllers. It provides the essential interface for monitoring process states in real-time while maintaining strict electrical separation between field circuits and the system backplane.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe DI830 organizes its 16 input channels into two distinct isolated groups to enhance signal reliability:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDI830 \/ 3BSE013210R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input (DI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Grouping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated in two groups of 8 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e119 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Depth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e102 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible MTUs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTU810, TU812, TU814, TU818, TU830, TU833, TU838, TU850\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS Directive 2011\/65\/EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Group Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module isolates 16 channels into two independent groups of eight. This architecture prevents a localized electrical fault or ground loop in one field segment from disrupting the entire I\/O cluster, significantly increasing fault tolerance in complex wiring environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Cabinet Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim 45 mm profile maximizes the number of digital inputs per linear decimeter of DIN rail. This high-density design reduces the required number of S800 I\/O stations and minimizes the overall footprint of the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Termination Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DI830 interfaces with a broad range of Module Termination Units (MTUs), including the TU810, TU818, and TU830. This flexibility allows engineers to select between screw, spring, or fused terminals to match specific site wiring standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Transient Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated filtering and isolation barrier protect the internal ModuleBus logic from electromagnetic interference (EMI) and voltage spikes common in heavy industrial settings. This ensures stable state detection even near large motors or switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen paired with a compatible MTU, the DI830 supports Removal and Insertion Under Power (RIUP). Maintenance teams can replace a module without shutting down the controller or interrupting the communication to other modules in the same cluster.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field voltage does the DI830 typically support?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DI830 standardizes on 24V DC input signals. Always verify that your field power supply matches the specific voltage threshold requirements defined in the S800 technical manual to ensure accurate state detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a factory-sealed unit?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. We guarantee this DI830 (3BSE013210R1) is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal ABB hardware. It arrives in original factory packaging with all security labels and technical documentation intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix the DI830 with other S800 module types?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The DI830 integrates seamlessly with any other S800 I\/O modules (Analog, Pulse, or Output) on the same ModuleBus, provided the Fieldbus Communication Interface (FCI) has sufficient addressing capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle signal debounce?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware includes internal digital filtering to eliminate \"contact bounce\" from mechanical field switches. You can further configure these filter times within the ABB Control Builder software to match the specific characteristics of your field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53096085848248,"sku":"DI830 3BSE013210R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DI8303BSE013210R1.jpg?v=1774432253","url":"https:\/\/www.globalpetroparts.com\/products\/di830-abb-3bse013210r1-16-channel-digital-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}