{"product_id":"digital-output-module-honeywell-fc-sdo-0824","title":"Digital Output Module Honeywell FC-SDO-0824","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-SDO-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager (SM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It is designed to drive 24 VDC field actuators such as solenoids, relays, and shutdown valves within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Instrumented Systems (SIS)\u003c\/strong\u003e. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 independent, supervised output channels\u003c\/strong\u003e, the module ensures that critical safety commands are executed reliably and predictably.\u003c\/p\u003e\n\u003cp\u003eA key strength of the FC-SDO-0824 is its advanced diagnostic capability. Each output channel is continuously monitored for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshort circuits, open lines, and internal faults\u003c\/strong\u003e, enabling proactive fault detection essential for achieving\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem performance. Its robust electronic design supports inductive loads while delivering stable switching for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmergency Shutdown (ESD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFire \u0026amp; Gas (F\u0026amp;G)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eFC-SDO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003e8 Digital (Discrete) Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSourcing (Current-supplying)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacity\u003c\/td\u003e\n\u003ctd\u003eHigh-current capable (solenoid\/actuator drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Supervision\u003c\/td\u003e\n\u003ctd\u003eLine monitoring (short circuit \u0026amp; open loop detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between logic and field circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 2 \/ SIL 3 capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED status indicators per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003ePassive convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell Safety Manager I\/O width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eSystem Integration \u0026amp; Reliability\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-SDO-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einstalls directly into the Safety Manager I\/O chassis and communicates with the safety processor via high-speed, redundant system buses. Outputs are designed to transition to a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efail-safe state\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(typically de-energized) upon loss of communication or internal fault, ensuring the process is driven to a safe condition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmergency Shutdown (ESD):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIsolation and shutdown valve control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFire \u0026amp; Gas Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDeluge valve and suppression solenoid activation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBurner Management Systems (BMS):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSafe actuation of fuel gas valves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the FC-SDO-0824 support field wiring line monitoring?\u003c\/strong\u003e\u003cbr\u003eYes. The module continuously supervises each output channel, detecting open circuits and short circuits and reporting faults immediately to the Safety Manager controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in redundant output configurations?\u003c\/strong\u003e\u003cbr\u003eYes. Although highly reliable as a standalone module, the FC-SDO-0824 is commonly deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1oo2 or 2oo2 architectures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto increase availability and reduce nuisance trips in critical safety applications.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52495028224184,"sku":"FC-SDO-0824","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FC-SDO-0824.jpg?v=1769153720","url":"https:\/\/www.globalpetroparts.com\/products\/digital-output-module-honeywell-fc-sdo-0824","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}