{"product_id":"do2401-7400209-030-triconex-digital-output-baseplate","title":"DO2401 7400209-030 Triconex Digital Output Baseplate","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong data-start=\"301\" data-end=\"323\"\u003eDO2401 7400209-030\u003c\/strong\u003e digital output baseplate provides essential structural support for Triconex safety and control systems.\u003cbr data-start=\"427\" data-end=\"430\"\u003eMoreover, it enables secure connection between digital output modules and system backplane architecture.\u003cbr data-start=\"534\" data-end=\"537\"\u003eIn addition, engineers rely on \u003cstrong data-start=\"568\" data-end=\"590\"\u003eDO2401 7400209-030\u003c\/strong\u003e to maintain stable signal distribution in industrial automation environments.\u003cbr data-start=\"668\" data-end=\"671\"\u003eTherefore, the baseplate ensures consistent system performance in mission-critical applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDO2401 7400209-030\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eTriconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eTriconex TMR Safety Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDigital output module mounting and signal routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003eMulti-module configuration (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Type\u003c\/td\u003e\n\u003ctd\u003eBackplane data communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eEdge connector backplane interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Modules\u003c\/td\u003e\n\u003ctd\u003eDigital output modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Distribution\u003c\/td\u003e\n\u003ctd\u003eIntegrated backplane power routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC system supply (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDepends on installed module configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Capacity\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent load distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eTMR system compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Support\u003c\/td\u003e\n\u003ctd\u003eSupported in configured system environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 480 × 300 × 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 4.0–6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eRack-mounted chassis installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5%–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade vibration tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003eSuitable for control cabinet environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI Protection\u003c\/td\u003e\n\u003ctd\u003eShielded industrial design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage\u003c\/td\u003e\n\u003ctd\u003eNo internal energy storage components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the function of the\u003cspan\u003e \u003c\/span\u003eDO2401 7400209-030\u003cspan\u003e \u003c\/span\u003ebaseplate?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO2401 7400209-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports mounting and connection of digital output modules in Triconex systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is the\u003cspan\u003e \u003c\/span\u003eDO2401 7400209-030\u003cspan\u003e \u003c\/span\u003ecompatible with TMR systems?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO2401 7400209-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis fully compatible with Triconex TMR architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the\u003cspan\u003e \u003c\/span\u003eDO2401 7400209-030\u003cspan\u003e \u003c\/span\u003esupport system expansion?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO2401 7400209-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports modular expansion depending on system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What industries use the\u003cspan\u003e \u003c\/span\u003eDO2401 7400209-030?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO2401 7400209-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in oil, gas, petrochemical, and power industries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How fast can you ship the\u003cspan\u003e \u003c\/span\u003eDO2401 7400209-030?\u003c\/strong\u003e\u003cbr\u003eWe usually ship within three days to two weeks depending on order size and logistics arrangements.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":53296253796536,"sku":"DO2401 7400209-030","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DO24017400209-030TriconexDigitalOutputBaseplate_3.jpg?v=1776136412","url":"https:\/\/www.globalpetroparts.com\/products\/do2401-7400209-030-triconex-digital-output-baseplate","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}